Class: Aws::IoTSiteWise::Types::DescribeGatewayCapabilityConfigurationResponse
- Inherits:
-
Struct
- Object
- Struct
- Aws::IoTSiteWise::Types::DescribeGatewayCapabilityConfigurationResponse
- Includes:
- Structure
- Defined in:
- lib/aws-sdk-iotsitewise/types.rb
Constant Summary collapse
- SENSITIVE =
[]
Instance Attribute Summary collapse
-
#capability_configuration ⇒ String
The JSON document that defines the gateway capability’s configuration.
-
#capability_namespace ⇒ String
The namespace of the gateway capability.
-
#capability_sync_status ⇒ String
The synchronization status of the capability configuration.
-
#gateway_id ⇒ String
The ID of the gateway that defines the capability configuration.
Instance Attribute Details
#capability_configuration ⇒ String
The JSON document that defines the gateway capability’s configuration. For more information, see [Configuring data sources (CLI)] in the *IoT SiteWise User Guide*.
[1]: docs.aws.amazon.com/iot-sitewise/latest/userguide/configure-sources.html#configure-source-cli
5014 5015 5016 5017 5018 5019 5020 5021 |
# File 'lib/aws-sdk-iotsitewise/types.rb', line 5014 class DescribeGatewayCapabilityConfigurationResponse < Struct.new( :gateway_id, :capability_namespace, :capability_configuration, :capability_sync_status) SENSITIVE = [] include Aws::Structure end |
#capability_namespace ⇒ String
The namespace of the gateway capability.
5014 5015 5016 5017 5018 5019 5020 5021 |
# File 'lib/aws-sdk-iotsitewise/types.rb', line 5014 class DescribeGatewayCapabilityConfigurationResponse < Struct.new( :gateway_id, :capability_namespace, :capability_configuration, :capability_sync_status) SENSITIVE = [] include Aws::Structure end |
#capability_sync_status ⇒ String
The synchronization status of the capability configuration. The sync status can be one of the following:
-
‘IN_SYNC` – The gateway is running the capability configuration.
-
‘NOT_APPLICABLE` – Synchronization is not required for this capability configuration. This is most common when integrating partner data sources, because the data integration is handled externally by the partner.
-
‘OUT_OF_SYNC` – The gateway hasn’t received the capability configuration.
-
‘SYNC_FAILED` – The gateway rejected the capability configuration.
-
‘UNKNOWN` – The synchronization status is currently unknown due to an undetermined or temporary error.
5014 5015 5016 5017 5018 5019 5020 5021 |
# File 'lib/aws-sdk-iotsitewise/types.rb', line 5014 class DescribeGatewayCapabilityConfigurationResponse < Struct.new( :gateway_id, :capability_namespace, :capability_configuration, :capability_sync_status) SENSITIVE = [] include Aws::Structure end |
#gateway_id ⇒ String
The ID of the gateway that defines the capability configuration.
5014 5015 5016 5017 5018 5019 5020 5021 |
# File 'lib/aws-sdk-iotsitewise/types.rb', line 5014 class DescribeGatewayCapabilityConfigurationResponse < Struct.new( :gateway_id, :capability_namespace, :capability_configuration, :capability_sync_status) SENSITIVE = [] include Aws::Structure end |