Class: ViewModel::SapSchema102::Rdsap
Instance Method Summary
collapse
#address_id, #address_line1, #address_line2, #address_line3, #address_line4, #all_floor_descriptions, #all_floor_energy_efficiency_rating, #all_floor_env_energy_efficiency_rating, #all_main_heating_controls_descriptions, #all_main_heating_controls_energy_efficiency, #all_main_heating_controls_environmental_efficiency, #all_main_heating_descriptions, #all_main_heating_energy_efficiency, #all_main_heating_environmental_efficiency, #all_roof_descriptions, #all_roof_energy_efficiency_rating, #all_roof_env_energy_efficiency_rating, #all_wall_descriptions, #all_wall_energy_efficiency_rating, #all_wall_env_energy_efficiency_rating, #assessment_id, #assessor_email, #assessor_name, #assessor_telephone, #built_form, #co2_emissions_current_per_floor_area, #country_code, #current_carbon_emission, #current_energy_rating, #current_space_heating_demand, #current_water_heating_demand, #cylinder_insul_thickness, #cylinder_insulation_type, #cylinder_size, #date_of_assessment, #date_of_expiry, #date_of_registration, #dwelling_type, #energy_consumption_potential, #environmental_impact_current, #environmental_impact_potential, #estimated_energy_cost, #extensions_count, #fixed_lighting_outlets_count, #floor_level, #heat_loss_corridor, #heating_cost_current, #heating_cost_potential, #hot_water_cost_current, #hot_water_cost_potential, #hot_water_description, #hot_water_energy_efficiency_rating, #hot_water_environmental_efficiency_rating, #impact_of_cavity_insulation, #impact_of_loft_insulation, #impact_of_solid_wall_insulation, #improvements, #level, #lighting_cost_current, #lighting_cost_potential, #lighting_description, #lighting_energy_efficiency_rating, #lighting_environmental_efficiency_rating, #low_energy_fixed_lighting_outlets_count, #low_energy_lighting, #main_fuel_type, #main_heating_controls, #multiple_glazed_proportion, #open_fireplaces_count, #postcode, #potential_carbon_emission, #potential_energy_rating, #potential_energy_saving, #primary_energy_use, #property_summary, #recommendations_for_report, #related_party_disclosure_text, #report_type, #scheme_assessor_id, #secondary_fuel_type, #secondary_heating_description, #secondary_heating_energy_efficiency_rating, #secondary_heating_environmental_efficiency_rating, #top_storey, #total_floor_area, #town, #type_of_assessment, #unheated_corridor_length, #wind_turbine_count, #window_description, #window_energy_efficiency_rating, #window_environmental_efficiency_rating
#addendum, #has_hot_water_cylinder, #improvement_title, #lzc_energy_sources, #main_heating_category, #multi_glazing_type, #property_type, #status, #water_heating_code
#initialize, #xpath
Instance Method Details
#construction_age_band ⇒ Object
8
9
10
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 8
def construction_age_band
xpath(%w[Construction-Year])
end
|
#energy_tariff ⇒ Object
61
62
63
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 61
def energy_tariff
xpath(%w[Meter-Type])
end
|
#floor_height ⇒ Object
53
54
55
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 53
def floor_height
@xml_doc.search("Room-Height").map(&:content)
end
|
#glazed_area ⇒ Object
33
34
35
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 33
def glazed_area
xpath(%w[Glazed-Area])
end
|
#habitable_room_count ⇒ Object
37
38
39
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 37
def habitable_room_count
xpath(%w[Habitable-Room-Count])&.to_i
end
|
#has_cylinder_thermostat ⇒ Object
65
66
67
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 65
def has_cylinder_thermostat
xpath(%w[Cylinder-Thermostat])
end
|
#heated_room_count ⇒ Object
41
42
43
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 41
def heated_room_count
xpath(%w[Heated-Room-Count])&.to_i
end
|
#main_dwelling_construction_age_band_or_year ⇒ Object
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 17
def main_dwelling_construction_age_band_or_year
sap_building_parts =
@xml_doc.xpath("//SAP-Building-Parts/SAP-Building-Part")
sap_building_parts.each do |sap_building_part|
identifier = sap_building_part.at("Identifier")
if identifier&.content == "Main Dwelling"
return(
sap_building_part.at_xpath(
"Construction-Age-Band | Construction-Year",
)&.content
)
end
end
nil
end
|
#mechanical_ventilation ⇒ Object
DO NOT CORRECT - this typo is present in the schema XML pre 12.0
13
14
15
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 13
def mechanical_ventilation
xpath(%w[Mechanical-Ventliation])
end
|
#photovoltaic_roof_area_percent ⇒ Object
45
46
47
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 45
def photovoltaic_roof_area_percent
xpath(%w[Photovoltaic-Supply])
end
|
#property_age_band ⇒ Object
4
5
6
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 4
def property_age_band
nil
end
|
#solar_water_heating_flag ⇒ Object
49
50
51
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 49
def solar_water_heating_flag
xpath(%w[Solar-Water-Heating])
end
|
#storey_count ⇒ Object
57
58
59
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 57
def storey_count
xpath(%w[Storey-Count])&.to_i
end
|
#water_heating_fuel ⇒ Object
69
70
71
|
# File 'lib/view_model/sap_schema_102/rdsap.rb', line 69
def water_heating_fuel
xpath(%w[Water-Heating-Fuel])
end
|