Class: SetCOPforSingleSpeedDXCoolingUnits

Inherits:
OpenStudio::Measure::ModelMeasure
  • Object
show all
Defined in:
lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb

Overview

start the measure

Instance Method Summary collapse

Instance Method Details

#arguments(model) ⇒ Object

define the arguments that the user will input



15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
# File 'lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb', line 15

def arguments(model)
  args = OpenStudio::Measure::OSArgumentVector.new

  # populate choice argument for constructions that are applied to surfaces in the model
  air_loop_handles = OpenStudio::StringVector.new
  air_loop_display_names = OpenStudio::StringVector.new

  # putting space types and names into hash
  air_loop_args = model.getAirLoopHVACs
  air_loop_args_hash = {}
  air_loop_args.each do |air_loop_arg|
    air_loop_args_hash[air_loop_arg.name.to_s] = air_loop_arg
  end

  # looping through sorted hash of air loops
  air_loop_args_hash.sort.map do |key, value|
    show_loop = false
    components = value.supplyComponents
    components.each do |component|
      if !component.to_CoilCoolingDXSingleSpeed.is_initialized # instead of if not component.to_CoilCoolingDXSingleSpeed.empty?
        show_loop = true
      end
    end
    if show_loop == true
      air_loop_handles << value.handle.to_s
      air_loop_display_names << key
    end
  end

  # add building to string vector with air loops
  building = model.getBuilding
  air_loop_handles << building.handle.to_s
  air_loop_display_names << '*All Air Loops*'

  # make an argument for air loops
  object = OpenStudio::Measure::OSArgument.makeChoiceArgument('object', air_loop_handles, air_loop_display_names, true)
  object.setDisplayName('Choose an Air Loop with a single speed DX Cooling Unit to Alter.')
  object.setDefaultValue('*All Air Loops*') # if no air loop is chosen this will run on all air loops
  args << object

  # make an argument to add new space true/false
  cop = OpenStudio::Measure::OSArgument.makeDoubleArgument('cop', true)
  cop.setDisplayName('Rated COP')
  cop.setDefaultValue(4.0)
  args << cop

  # bool argument to remove existing costs
  remove_costs = OpenStudio::Measure::OSArgument.makeBoolArgument('remove_costs', true)
  remove_costs.setDisplayName('Remove Baseline Costs From Effected Cooling Coil DX Single Speed Units?')
  remove_costs.setDefaultValue(true)
  args << remove_costs

  # make an argument for material and installation cost
  material_cost = OpenStudio::Measure::OSArgument.makeDoubleArgument('material_cost', true)
  material_cost.setDisplayName('Material and Installation Costs per Cooling Coil DX Single Speed Unit ($).')
  material_cost.setDefaultValue(0.0)
  args << material_cost

  # make an argument for demolition cost
  demolition_cost = OpenStudio::Measure::OSArgument.makeDoubleArgument('demolition_cost', true)
  demolition_cost.setDisplayName('Demolition Costs per Cooling Coil DX Single Speed Unit ($).')
  demolition_cost.setDefaultValue(0.0)
  args << demolition_cost

  # make an argument for duration in years until costs start
  years_until_costs_start = OpenStudio::Measure::OSArgument.makeIntegerArgument('years_until_costs_start', true)
  years_until_costs_start.setDisplayName('Years Until Costs Start (whole years).')
  years_until_costs_start.setDefaultValue(0)
  args << years_until_costs_start

  # make an argument to determine if demolition costs should be included in initial construction
  demo_cost_initial_const = OpenStudio::Measure::OSArgument.makeBoolArgument('demo_cost_initial_const', true)
  demo_cost_initial_const.setDisplayName('Demolition Costs Occur During Initial Construction?')
  demo_cost_initial_const.setDefaultValue(false)
  args << demo_cost_initial_const

  # make an argument for expected life
  expected_life = OpenStudio::Measure::OSArgument.makeIntegerArgument('expected_life', true)
  expected_life.setDisplayName('Expected Life (whole years).')
  expected_life.setDefaultValue(20)
  args << expected_life

  # make an argument for o&m cost
  om_cost = OpenStudio::Measure::OSArgument.makeDoubleArgument('om_cost', true)
  om_cost.setDisplayName('O & M Costs per Cooling Coil DX Single Speed Unit ($).')
  om_cost.setDefaultValue(0.0)
  args << om_cost

  # make an argument for o&m frequency
  om_frequency = OpenStudio::Measure::OSArgument.makeIntegerArgument('om_frequency', true)
  om_frequency.setDisplayName('O & M Frequency (whole years).')
  om_frequency.setDefaultValue(1)
  args << om_frequency

  return args
end

#get_total_costs_for_objects(objects) ⇒ Object

helper that loops through lifecycle costs getting total costs under “Construction” or “Salvage” category and add to counter if occurs during year 0



204
205
206
207
208
209
210
211
212
213
214
215
216
217
# File 'lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb', line 204

def get_total_costs_for_objects(objects)
  counter = 0
  objects.each do |object|
    object_LCCs = object.lifeCycleCosts
    object_LCCs.each do |object_LCC|
      if (object_LCC.category == 'Construction') || (object_LCC.category == 'Salvage')
        if object_LCC.yearsFromStart == 0
          counter += object_LCC.totalCost
        end
      end
    end
  end
  return counter
end

#nameObject

define the name that a user will see, this method may be deprecated as the display name in PAT comes from the name field in measure.xml



10
11
12
# File 'lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb', line 10

def name
  return 'Set COP for Single Speed DX Cooling Units'
end

#neat_numbers(number, roundto = 2) ⇒ Object

short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure



193
194
195
196
197
198
199
200
201
# File 'lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb', line 193

def neat_numbers(number, roundto = 2) # round to 0 or 2)
  if roundto == 2
    number = format '%.2f', number
  else
    number = number.round
  end
  # regex to add commas
  number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
end

#run(model, runner, user_arguments) ⇒ Object

define what happens when the measure is cop



113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
# File 'lib/measures/SetCOPforSingleSpeedDXCoolingUnits/measure.rb', line 113

def run(model, runner, user_arguments)
  super(model, runner, user_arguments)

  # use the built-in error checking
  if !runner.validateUserArguments(arguments(model), user_arguments)
    return false
  end

  # assign the user inputs to variables
  object = runner.getOptionalWorkspaceObjectChoiceValue('object', user_arguments, model) # model is passed in because of argument type
  cop = runner.getDoubleArgumentValue('cop', user_arguments)
  remove_costs = runner.getBoolArgumentValue('remove_costs', user_arguments)
  material_cost = runner.getDoubleArgumentValue('material_cost', user_arguments)
  demolition_cost = runner.getDoubleArgumentValue('demolition_cost', user_arguments)
  years_until_costs_start = runner.getIntegerArgumentValue('years_until_costs_start', user_arguments)
  demo_cost_initial_const = runner.getBoolArgumentValue('demo_cost_initial_const', user_arguments)
  expected_life = runner.getIntegerArgumentValue('expected_life', user_arguments)
  om_cost = runner.getDoubleArgumentValue('om_cost', user_arguments)
  om_frequency = runner.getIntegerArgumentValue('om_frequency', user_arguments)

  # check the air_loop for reasonableness
  apply_to_all_air_loops = false
  air_loop = nil
  if object.empty?
    handle = runner.getStringArgumentValue('air_loop', user_arguments)
    if handle.empty?
      runner.registerError('No air loop was chosen.')
    else
      runner.registerError("The selected air_loop with handle '#{handle}' was not found in the model. It may have been removed by another measure.")
    end
    return false
  else
    if !object.get.to_AirLoopHVAC.empty?
      air_loop = object.get.to_AirLoopHVAC.get
    elsif !object.get.to_Building.empty?
      apply_to_all_air_loops = true
    else
      runner.registerError('Script Error - argument not showing up as air loop.')
      return false
    end
  end

  # check the user_name for reasonableness
  if cop <= 0
    runner.registerError('Please enter a positive value for Rated COP.')
    return false
  end
  if cop > 10
    runner.registerWarning("The requested Rated COP of #{cop} seems unusually high")
  end

  # set flags to use later
  costs_requested = false

  # set values to use later
  yr0_capital_totalCosts_baseline = 0
  yr0_capital_totalCosts_proposed = 0

  # If demo_cost_initial_const is true then will be applied once in the lifecycle. Future replacements use the demo cost of the new construction.
  demo_costs_of_baseline_objects = 0

  # check costs for reasonableness
  if material_cost.abs + demolition_cost.abs + om_cost.abs == 0
    runner.registerInfo('No costs were requested for Coil Cooling DX Single Speed units.')
  else
    costs_requested = true
  end

  # check lifecycle arguments for reasonableness
  if (years_until_costs_start < 0) && (years_until_costs_start > expected_life)
    runner.registerError('Years until costs start should be a non-negative integer less than Expected Life.')
  end
  if (expected_life < 1) && (expected_life > 100)
    runner.registerError('Choose an integer greater than 0 and less than or equal to 100 for Expected Life.')
  end
  if om_frequency < 1
    runner.registerError('Choose an integer greater than 0 for O & M Frequency.')
  end

  # short def to make numbers pretty (converts 4125001.25641 to 4,125,001.26 or 4,125,001). The definition be called through this measure
  def neat_numbers(number, roundto = 2) # round to 0 or 2)
    if roundto == 2
      number = format '%.2f', number
    else
      number = number.round
    end
    # regex to add commas
    number.to_s.reverse.gsub(/([0-9]{3}(?=([0-9])))/, '\\1,').reverse
  end

  # helper that loops through lifecycle costs getting total costs under "Construction" or "Salvage" category and add to counter if occurs during year 0
  def get_total_costs_for_objects(objects)
    counter = 0
    objects.each do |object|
      object_LCCs = object.lifeCycleCosts
      object_LCCs.each do |object_LCC|
        if (object_LCC.category == 'Construction') || (object_LCC.category == 'Salvage')
          if object_LCC.yearsFromStart == 0
            counter += object_LCC.totalCost
          end
        end
      end
    end
    return counter
  end

  # get air loops for measure
  if apply_to_all_air_loops
    air_loops = model.getAirLoopHVACs
  else
    air_loops = []
    air_loops << air_loop # only run on a single space type
  end

  # get cop values
  initial_cop_values = []
  missing_initial_cop = 0

  # loop through air loops
  air_loops.each do |air_loop|
    supply_components = air_loop.supplyComponents

    # find single speed dx units on loop
    supply_components.each do |supply_component|
      hVACComponent = supply_component.to_CoilCoolingDXSingleSpeed
      if !hVACComponent.empty?
        hVACComponent = hVACComponent.get

        # change and report high speed cop. Prior to 3.5.0 it was an OptionalDouble
        initial_cop = OpenStudio::OptionalDouble.new(hVACComponent.ratedCOP)
        if !initial_cop.empty?
          runner.registerInfo("Changing the Rated COP from #{initial_cop.get} to #{cop} for single speed dx unit '#{hVACComponent.name}' on air loop '#{air_loop.name}'")
          initial_cop_values << initial_cop.get
          optionalDoubleCOP = OpenStudio::OptionalDouble.new(cop)
          hVACComponent.setRatedCOP(optionalDoubleCOP)
        else
          runner.registerInfo("Setting the Rated COP to #{cop} for single speed dx unit '#{hVACComponent.name}' on air loop '#{air_loop.name}. The original object did not have a Rated COP value'")
          missing_initial_cop += 1
          hVACComponent.setRatedCOP(cop)
        end

        # get initial year 0 cost
        yr0_capital_totalCosts_baseline += get_total_costs_for_objects([hVACComponent])

        # demo value of baseline costs associated with unit
        demo_LCCs = hVACComponent.lifeCycleCosts
        demo_LCCs.each do |demo_LCC|
          if demo_LCC.category == 'Salvage'
            demo_costs_of_baseline_objects += demo_LCC.totalCost
          end
        end

        # remove all old costs to mimic replacement of component vs. an upgrade
        if !hVACComponent.lifeCycleCosts.empty? && (remove_costs == true)
          runner.registerInfo("Removing existing lifecycle cost objects associated with #{hVACComponent.name}")
          removed_costs = hVACComponent.removeLifeCycleCosts
          costs_removed = true
        end

        # add new costs
        if costs_requested == true

          # adding new cost items
          lcc_mat = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_Mat - #{hVACComponent.name}", hVACComponent, material_cost, 'CostPerEach', 'Construction', expected_life, years_until_costs_start)
          # cost for if demo_initial_Construction == true is added at the end of the measure
          lcc_demo = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_Demo - #{hVACComponent.name}", hVACComponent, demolition_cost, 'CostPerEach', 'Salvage', expected_life, years_until_costs_start + expected_life)
          lcc_om = OpenStudio::Model::LifeCycleCost.createLifeCycleCost("LCC_OM - #{hVACComponent.name}", hVACComponent, om_cost, 'CostPerEach', 'Maintenance', om_frequency, 0)

          # get final year 0 cost
          yr0_capital_totalCosts_proposed += get_total_costs_for_objects([hVACComponent])

        end

      end
    end
  end

  # add one time demo cost of removed object
  if demo_cost_initial_const == true
    building = model.getBuilding
    lcc_baseline_demo = OpenStudio::Model::LifeCycleCost.createLifeCycleCost('LCC_baseline_demo', building, demo_costs_of_baseline_objects, 'CostPerEach', 'Salvage', 0, years_until_costs_start).get # using 0 for repeat period since one time cost.
    runner.registerInfo("Adding one time cost of $#{neat_numbers(lcc_baseline_demo.totalCost, 0)} related to demolition of baseline objects.")

    # if demo occurs on year 0 then add to initial capital cost counter
    if lcc_baseline_demo.yearsFromStart == 0
      yr0_capital_totalCosts_proposed += lcc_baseline_demo.totalCost
    end
  end

  # reporting initial condition of model
  runner.registerInitialCondition("The starting Rated COP values in affected loop(s) range from #{initial_cop_values.min} to #{initial_cop_values.max}. Initial year 0 capital costs for affected Coil Cooling DX Single Speed units is $#{neat_numbers(yr0_capital_totalCosts_baseline, 0)}.")

  if initial_cop_values.size + missing_initial_cop == 0
    runner.registerAsNotApplicable('The affected loop(s) does not contain any single speed DX cooling units, the model will not be altered.')
    return true
  end

  # reporting final condition of model
  runner.registerFinalCondition("#{initial_cop_values.size + missing_initial_cop} single speed dx units had their Rated COP values set to #{cop}. Final year 0 capital costs for affected Coil Cooling DX Single Speed units is $#{neat_numbers(yr0_capital_totalCosts_proposed, 0)}.")

  return true
end