Class: NRELZNEReady2017MidriseApartment
- Inherits:
-
NRELZNEReady2017
- Object
- Standard
- ASHRAE901
- NRELZNEReady2017
- NRELZNEReady2017MidriseApartment
- Defined in:
- lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb
Overview
This class represents a prototypical NRELZNEReady2017 MidriseApartment.
Constant Summary collapse
- @@building_type =
"MidriseApartment"
Constants inherited from Standard
Instance Attribute Summary collapse
-
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
-
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
-
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
-
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
-
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
-
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
-
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
Attributes inherited from NRELZNEReady2017
Attributes inherited from Standard
#space_multiplier_map, #standards_data, #template
Instance Method Summary collapse
-
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
-
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
-
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
-
#initialize ⇒ NRELZNEReady2017MidriseApartment
constructor
A new instance of NRELZNEReady2017MidriseApartment.
-
#model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Bool
Makes changes to the daylighting sensors that are too specific to be coded generically.
-
#model_get_lookup_name(building_type) ⇒ String
Get the name of the building type used in lookups.
-
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_exhaust_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb.
Methods inherited from NRELZNEReady2017
#air_loop_hvac_apply_energy_recovery_ventilator_efficiency, #air_loop_hvac_dcv_required_when_erv, #air_loop_hvac_demand_control_ventilation_limits, #air_loop_hvac_economizer_limits, #air_loop_hvac_economizer_type_allowable?, #air_loop_hvac_energy_recovery_ventilator_flow_limit, #air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type, #air_loop_hvac_energy_recovery_ventilator_required?, #air_loop_hvac_energy_recovery_ventilator_type, #air_loop_hvac_integrated_economizer_required?, #air_loop_hvac_motorized_oa_damper_limits, #air_loop_hvac_multizone_vav_optimization_required?, #air_loop_hvac_single_zone_controls_num_stages, #air_loop_hvac_supply_air_temperature_reset_required?, #air_loop_hvac_unoccupied_threshold, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #air_terminal_single_duct_vav_reheat_minimum_damper_position, #cooling_tower_variable_speed_apply_efficiency_and_curves, #fan_constant_volume_airloop_fan_pressure_rise, #fan_on_off_airloop_or_unitary_fan_pressure_rise, #fan_variable_volume_airloop_fan_pressure_rise, #fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #heat_exchanger_air_to_air_sensible_and_latent_apply_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency, #load_standards_database, #model_apply_hvac_efficiency_standard, #model_cw_loop_cooling_tower_fan_type, #model_economizer_type, #model_elevator_fan_pwr, #model_elevator_lighting_pct_incandescent, #plant_loop_apply_prm_baseline_chilled_water_pumping_type, #plant_loop_apply_prm_baseline_hot_water_pumping_type, #space_daylighted_area_window_width, #space_daylighting_control_required?, #space_daylighting_fractions_and_windows, #space_infiltration_rate_75_pa, #thermal_zone_demand_control_ventilation_limits, #zone_hvac_component_prm_baseline_fan_efficacy
Methods included from NRELZNEReady2017CoolingTower
#cooling_tower_apply_minimum_power_per_flow_gpm_limit
Methods inherited from ASHRAE901
#fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #load_standards_database
Methods inherited from Standard
#adjust_infiltration_to_lower_pressure, #adjust_infiltration_to_prototype_building_conditions, #adjust_sizing_system, #afue_to_thermal_eff, #air_loop_hvac_add_motorized_oa_damper, #air_loop_hvac_adjust_minimum_vav_damper_positions, #air_loop_hvac_adjust_minimum_vav_damper_positions_outpatient, #air_loop_hvac_allowable_system_brake_horsepower, #air_loop_hvac_apply_baseline_fan_pressure_rise, #air_loop_hvac_apply_economizer_integration, #air_loop_hvac_apply_economizer_limits, #air_loop_hvac_apply_energy_recovery_ventilator, #air_loop_hvac_apply_energy_recovery_ventilator_efficiency, #air_loop_hvac_apply_maximum_reheat_temperature, #air_loop_hvac_apply_minimum_vav_damper_positions, #air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_apply_prm_baseline_controls, #air_loop_hvac_apply_prm_baseline_economizer, #air_loop_hvac_apply_prm_baseline_fan_power, #air_loop_hvac_apply_prm_sizing_temperatures, #air_loop_hvac_apply_single_zone_controls, #air_loop_hvac_apply_standard_controls, #air_loop_hvac_apply_vav_damper_action, #air_loop_hvac_data_center_area_served, #air_loop_hvac_dcv_required_when_erv, #air_loop_hvac_demand_control_ventilation_limits, #air_loop_hvac_demand_control_ventilation_required?, #air_loop_hvac_disable_multizone_vav_optimization, #air_loop_hvac_dx_cooling?, #air_loop_hvac_economizer?, #air_loop_hvac_economizer_limits, #air_loop_hvac_economizer_required?, #air_loop_hvac_economizer_type_allowable?, #air_loop_hvac_enable_demand_control_ventilation, #air_loop_hvac_enable_multizone_vav_optimization, #air_loop_hvac_enable_optimum_start, #air_loop_hvac_enable_supply_air_temperature_reset_delta, #air_loop_hvac_enable_supply_air_temperature_reset_outdoor_temperature, #air_loop_hvac_enable_supply_air_temperature_reset_warmest_zone, #air_loop_hvac_enable_unoccupied_fan_shutoff, #air_loop_hvac_energy_recovery?, #air_loop_hvac_energy_recovery_ventilator_flow_limit, #air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type, #air_loop_hvac_energy_recovery_ventilator_required?, #air_loop_hvac_energy_recovery_ventilator_type, #air_loop_hvac_fan_power_limitation_pressure_drop_adjustment_brake_horsepower, #air_loop_hvac_find_design_supply_air_flow_rate, #air_loop_hvac_floor_area_served, #air_loop_hvac_floor_area_served_exterior_zones, #air_loop_hvac_floor_area_served_interior_zones, #air_loop_hvac_get_occupancy_schedule, #air_loop_hvac_humidifier_count, #air_loop_hvac_include_hydronic_cooling_coil?, #air_loop_hvac_include_wshp?, #air_loop_hvac_integrated_economizer_required?, #air_loop_hvac_motorized_oa_damper_limits, #air_loop_hvac_motorized_oa_damper_required?, #air_loop_hvac_multi_stage_dx_cooling?, #air_loop_hvac_multizone_vav_optimization_required?, #air_loop_hvac_multizone_vav_system?, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_prm_baseline_economizer_required?, #air_loop_hvac_prm_economizer_type_and_limits, #air_loop_hvac_remove_motorized_oa_damper, #air_loop_hvac_residential_area_served, #air_loop_hvac_set_minimum_damper_position, #air_loop_hvac_single_zone_controls_num_stages, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_supply_air_temperature_reset_required?, #air_loop_hvac_supply_return_exhaust_relief_fans, #air_loop_hvac_system_fan_brake_horsepower, #air_loop_hvac_system_multiplier, #air_loop_hvac_terminal_reheat?, #air_loop_hvac_total_cooling_capacity, #air_loop_hvac_unitary_system?, #air_loop_hvac_unoccupied_fan_shutoff_required?, #air_loop_hvac_unoccupied_threshold, #air_loop_hvac_vav_damper_action, #air_loop_hvac_vav_system?, #air_terminal_single_duct_parallel_piu_reheat_apply_prm_baseline_fan_power, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #air_terminal_single_duct_vav_reheat_apply_minimum_damper_position, #air_terminal_single_duct_vav_reheat_minimum_damper_position, #air_terminal_single_duct_vav_reheat_reheat_type, #air_terminal_single_duct_vav_reheat_set_heating_cap, #apply_changes_to_surface_construction, #apply_lighting_schedule, #apply_limit_to_subsurface_ratio, #apply_max_fdwr, #apply_max_srr, #boiler_hot_water_apply_efficiency_and_curves, #boiler_hot_water_find_capacity, #boiler_hot_water_find_search_criteria, #boiler_hot_water_standard_minimum_thermal_efficiency, build, #building_story_floor_multiplier, #building_story_minimum_z_value, #change_construction_properties_in_model, #chiller_electric_eir_apply_efficiency_and_curves, #chiller_electric_eir_find_capacity, #chiller_electric_eir_find_search_criteria, #chiller_electric_eir_standard_minimum_full_load_efficiency, #coil_cooling_dx_multi_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_find_capacity, #coil_cooling_dx_single_speed_standard_minimum_cop, #coil_cooling_dx_two_speed_apply_efficiency_and_curves, #coil_cooling_dx_two_speed_find_capacity, #coil_cooling_dx_two_speed_standard_minimum_cop, #coil_cooling_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_cooling_water_to_air_heat_pump_find_capacity, #coil_cooling_water_to_air_heat_pump_standard_minimum_cop, #coil_heating_dx_multi_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_apply_defrost_eir_curve_limits, #coil_heating_dx_single_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_find_capacity, #coil_heating_dx_single_speed_standard_minimum_cop, #coil_heating_gas_apply_efficiency_and_curves, #coil_heating_gas_apply_prototype_efficiency, #coil_heating_gas_multi_stage_apply_efficiency_and_curves, #coil_heating_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_heating_water_to_air_heat_pump_find_capacity, #coil_heating_water_to_air_heat_pump_standard_minimum_cop, #combustion_eff_to_thermal_eff, #construction_calculated_solar_heat_gain_coefficient, #construction_calculated_u_factor, #construction_calculated_visible_transmittance, #construction_deep_copy, #construction_set_glazing_shgc, #construction_set_glazing_tvis, #construction_set_glazing_u_value, #construction_set_slab_f_factor, #construction_set_u_value, #construction_set_underground_wall_c_factor, #construction_simple_glazing?, #controller_water_coil_set_convergence_limits, #convert_curve_biquadratic, #cooling_tower_single_speed_apply_efficiency_and_curves, #cooling_tower_two_speed_apply_efficiency_and_curves, #cooling_tower_variable_speed_apply_efficiency_and_curves, #cop_heating_to_cop_heating_no_fan, #cop_to_eer, #cop_to_kw_per_ton, #cop_to_seer, #create_air_conditioner_variable_refrigerant_flow, #create_boiler_hot_water, #create_central_air_source_heat_pump, #create_coil_cooling_dx_single_speed, #create_coil_cooling_dx_two_speed, #create_coil_cooling_water, #create_coil_cooling_water_to_air_heat_pump_equation_fit, #create_coil_heating_dx_single_speed, #create_coil_heating_electric, #create_coil_heating_gas, #create_coil_heating_water, #create_coil_heating_water_to_air_heat_pump_equation_fit, #create_curve_bicubic, #create_curve_biquadratic, #create_curve_cubic, #create_curve_exponent, #create_curve_quadratic, #create_fan_constant_volume, #create_fan_constant_volume_from_json, #create_fan_on_off, #create_fan_on_off_from_json, #create_fan_variable_volume, #create_fan_variable_volume_from_json, #create_fan_zone_exhaust, #create_fan_zone_exhaust_from_json, #day_schedule_equivalent_full_load_hrs, #define_space_multiplier, #eer_to_cop, #fan_constant_volume_airloop_fan_pressure_rise, #fan_constant_volume_apply_prototype_fan_pressure_rise, #fan_on_off_airloop_or_unitary_fan_pressure_rise, #fan_on_off_apply_prototype_fan_pressure_rise, #fan_variable_volume_airloop_fan_pressure_rise, #fan_variable_volume_apply_prototype_fan_pressure_rise, #fan_variable_volume_cooling_system_type, #fan_variable_volume_part_load_fan_power_limitation?, #fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #fan_variable_volume_set_control_type, #fan_zone_exhaust_apply_prototype_fan_pressure_rise, #film_coefficients_r_value, #find_and_set_insulation_layer, #find_exposed_conditioned_roof_surfaces, #find_exposed_conditioned_vertical_surfaces, #find_highest_roof_centre, #fluid_cooler_apply_minimum_power_per_flow, #get_outdoor_subsurface_ratio, #headered_pumps_variable_speed_set_control_type, #heat_exchanger_air_to_air_sensible_and_latent_apply_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_nominal_electric_power, #heat_exchanger_air_to_air_sensible_and_latent_minimum_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency, #heating_design_outdoor_temperatures, #hspf_to_cop_heating_no_fan, #hspf_to_cop_heating_with_fan, #intialize, #kw_per_ton_to_cop, #load_hvac_map, #load_initial_osm, #load_standards_database, #model_add_baseboard, #model_add_booster_swh_end_uses, #model_add_cav, #model_add_central_air_source_heat_pump, #model_add_chw_loop, #model_add_constant_schedule_ruleset, #model_add_construction, #model_add_construction_set, #model_add_crac, #model_add_crah, #model_add_curve, #model_add_cw_loop, #model_add_data_center_hvac, #model_add_data_center_load, #model_add_daylighting_controls, #model_add_design_days_and_weather_file, #model_add_district_ambient_loop, #model_add_doas, #model_add_doas_cold_supply, #model_add_elevator, #model_add_elevators, #model_add_evap_cooler, #model_add_exhaust_fan, #model_add_four_pipe_fan_coil, #model_add_furnace_central_ac, #model_add_ground_hx_loop, #model_add_ground_temperatures, #model_add_heatpump_water_heater, #model_add_high_temp_radiant, #model_add_hp_loop, #model_add_hvac, #model_add_hvac_system, #model_add_hw_loop, #model_add_ideal_air_loads, #model_add_low_temp_radiant, #model_add_material, #model_add_minisplit_hp, #model_add_piping_losses_to_swh_system, #model_add_prm_baseline_system, #model_add_psz_ac, #model_add_psz_vav, #model_add_ptac, #model_add_pthp, #model_add_pvav, #model_add_pvav_pfp_boxes, #model_add_radiant_proportional_controls, #model_add_refrigeration_case, #model_add_refrigeration_compressor, #model_add_refrigeration_system, #model_add_refrigeration_walkin, #model_add_schedule, #model_add_schedule_type_limits, #model_add_split_ac, #model_add_swh, #model_add_swh_booster, #model_add_swh_end_uses, #model_add_swh_end_uses_by_space, #model_add_swh_end_uses_by_spaceonly, #model_add_swh_loop, #model_add_typical_exterior_lights, #model_add_typical_refrigeration, #model_add_typical_swh, #model_add_unitheater, #model_add_vav_pfp_boxes, #model_add_vav_reheat, #model_add_vrf, #model_add_water_heater, #model_add_water_source_hp, #model_add_waterside_economizer, #model_add_window_ac, #model_add_zone_erv, #model_add_zone_ventilation, #model_apply_hvac_efficiency_standard, #model_apply_infiltration_standard, #model_apply_multizone_vav_outdoor_air_sizing, #model_apply_parametric_schedules, #model_apply_prm_baseline_skylight_to_roof_ratio, #model_apply_prm_baseline_window_to_wall_ratio, #model_apply_prm_construction_types, #model_apply_prm_sizing_parameters, #model_apply_standard_constructions, #model_assign_spaces_to_stories, #model_attach_water_fixtures_to_spaces?, #model_baseline_system_vav_fan_type, #model_create_exterior_lighting_area_length_count_hash, #model_create_prm_baseline_building, #model_create_prm_baseline_building_requires_vlt_sizing_run, #model_create_space_type_hash, #model_create_story_hash, #model_cw_loop_cooling_tower_fan_type, #model_differentiate_primary_secondary_thermal_zones, #model_effective_num_stories, #model_elevator_fan_pwr, #model_elevator_lift_power, #model_elevator_lighting_pct_incandescent, #model_eliminate_outlier_zones, #model_find_and_add_construction, #model_find_ashrae_hot_water_demand, #model_find_climate_zone_set, #model_find_constructions, #model_find_icc_iecc_2015_hot_water_demand, #model_find_icc_iecc_2015_internal_loads, #model_find_object, #model_find_objects, #model_find_prototype_floor_area, #model_find_target_eui, #model_find_target_eui_by_end_use, #model_find_water_heater_capacity_volume_and_parasitic, #model_get_baseline_system_type_by_zone, #model_get_building_climate_zone_and_building_type, #model_get_climate_zone_set_from_list, #model_get_construction_properties, #model_get_full_weather_file_path, #model_get_or_add_ambient_water_loop, #model_get_or_add_chilled_water_loop, #model_get_or_add_ground_hx_loop, #model_get_or_add_heat_pump_loop, #model_get_or_add_hot_water_loop, #model_get_story_for_nominal_z_coordinate, #model_group_zones_by_story, #model_infer_hours_of_operation_building, #model_legacy_results_by_end_use_and_fuel_type, #model_make_name, #model_num_stories_spanned, #model_prm_baseline_system_change_fuel_type, #model_prm_baseline_system_group_minimum_area, #model_prm_baseline_system_groups, #model_prm_baseline_system_number, #model_prm_baseline_system_type, #model_prm_skylight_to_roof_ratio_limit, #model_process_results_for_datapoint, #model_remap_office, #model_remove_external_shading_devices, #model_remove_prm_ems_objects, #model_remove_prm_hvac, #model_remove_unused_resource_objects, #model_residential_and_nonresidential_floor_areas, #model_set_climate_zone, #model_setup_parametric_schedules, #model_standards_climate_zone, #model_system_outdoor_air_sizing_vrp_method, #model_typical_display_case_zone, #model_typical_hvac_system_type, #model_typical_walkin_zone, #model_validate_standards_spacetypes_in_model, #model_ventilation_method, #model_walkin_freezer_latent_case_credit_curve, #model_zones_with_occ_and_fuel_type, #planar_surface_apply_standard_construction, #plant_loop_apply_prm_baseline_chilled_water_pumping_type, #plant_loop_apply_prm_baseline_chilled_water_temperatures, #plant_loop_apply_prm_baseline_condenser_water_pumping_type, #plant_loop_apply_prm_baseline_condenser_water_temperatures, #plant_loop_apply_prm_baseline_hot_water_pumping_type, #plant_loop_apply_prm_baseline_hot_water_temperatures, #plant_loop_apply_prm_baseline_pump_power, #plant_loop_apply_prm_baseline_pumping_type, #plant_loop_apply_prm_baseline_temperatures, #plant_loop_apply_prm_number_of_boilers, #plant_loop_apply_prm_number_of_chillers, #plant_loop_apply_prm_number_of_cooling_towers, #plant_loop_apply_standard_controls, #plant_loop_capacity_W_by_maxflow_and_deltaT_forwater, #plant_loop_enable_supply_water_temperature_reset, #plant_loop_find_maximum_loop_flow_rate, #plant_loop_prm_baseline_condenser_water_temperatures, #plant_loop_supply_water_temperature_reset_required?, #plant_loop_swh_loop?, #plant_loop_swh_system_type, #plant_loop_total_cooling_capacity, #plant_loop_total_floor_area_served, #plant_loop_total_heating_capacity, #plant_loop_total_rated_w_per_gpm, #plant_loop_variable_flow_system?, #pump_variable_speed_set_control_type, register_standard, #remove_All_Subsurfaces, #remove_HVAC, #remove_air_loops, #remove_all_HVAC, #remove_all_plant_loops, #remove_all_zone_equipment, #remove_plant_loops, #remove_unused_curves, #remove_vrf, #remove_zone_equipment, #rename_air_loop_nodes, #rename_plant_loop_nodes, #safe_load_model, #safe_load_sql, #schedule_apply_parametric_inputs, #schedule_compact_annual_min_max_value, #schedule_constant_annual_equivalent_full_load_hrs, #schedule_constant_annual_min_max_value, #schedule_ruleset_annual_equivalent_full_load_hrs, #schedule_ruleset_annual_hourly_values, #schedule_ruleset_annual_hours_above_value, #schedule_ruleset_annual_min_max_value, #schedule_ruleset_cleanup_profiles, #schedule_ruleset_set_hours_of_operation, #seer_to_cop_cooling_no_fan, #seer_to_cop_cooling_with_fan, #set_VAV_terminals_to_control_for_outdoor_air, #set_Window_To_Wall_Ratio_set_name, #space_add_daylighting_controls, #space_apply_infiltration_rate, #space_conditioning_category, #space_cooled?, #space_daylighted_area_window_width, #space_daylighted_areas, #space_daylighting_control_required?, #space_daylighting_fractions_and_windows, #space_design_internal_load, #space_exterior_wall_and_roof_and_subsurface_area, #space_exterior_wall_and_window_area, #space_get_adjacent_space_with_most_shared_wall_area, #space_get_adjacent_spaces_with_shared_wall_areas, #space_heated?, #space_hours_of_operation, #space_infiltration_rate_75_pa, #space_plenum?, #space_residential?, #space_sidelighting_effective_aperture, #space_skylight_effective_aperture, #space_type_apply_internal_load_schedules, #space_type_apply_internal_loads, #space_type_apply_rendering_color, #space_type_get_construction_properties, #space_type_get_standards_data, #spaces_get_occupancy_schedule, #spaces_hours_of_operation, #standard_design_sizing_temperatures, #standards_lookup_table_first, #standards_lookup_table_many, #strip_model, #sub_surface_component_infiltration_rate, #sub_surface_create_centered_subsurface_from_scaled_surface, #sub_surface_create_scaled_subsurfaces_from_surface, #sub_surface_reduce_area_by_percent_by_raising_sill, #sub_surface_reduce_area_by_percent_by_shrinking_toward_centroid, #sub_surface_vertical_rectangle?, #surface_component_infiltration_rate, #surface_replace_existing_subsurfaces_with_centered_subsurface, #thermal_eff_to_afue, #thermal_eff_to_comb_eff, #thermal_zone_add_exhaust, #thermal_zone_add_exhaust_fan_dcv, #thermal_zone_add_unconditioned_thermostat, #thermal_zone_apply_prm_baseline_supply_temperatures, #thermal_zone_building_type, #thermal_zone_conditioning_category, #thermal_zone_convert_oa_req_to_per_area, #thermal_zone_cooled?, #thermal_zone_demand_control_ventilation_limits, #thermal_zone_demand_control_ventilation_required?, #thermal_zone_design_internal_load, #thermal_zone_exhaust_fan_dcv_required?, #thermal_zone_floor_area_with_zone_multipliers, #thermal_zone_fossil_hybrid_or_purchased_heat?, #thermal_zone_fossil_or_electric_type, #thermal_zone_get_adjacent_zones_with_shared_wall_areas, #thermal_zone_get_occupancy_schedule, #thermal_zone_heated?, #thermal_zone_infer_system_type, #thermal_zone_majority_space_type, #thermal_zone_mixed_heating_fuel?, #thermal_zone_occupancy_type, #thermal_zone_outdoor_airflow_rate, #thermal_zone_outdoor_airflow_rate_per_area, #thermal_zone_plenum?, #thermal_zone_prm_baseline_cooling_design_supply_temperature, #thermal_zone_prm_baseline_heating_design_supply_temperature, #thermal_zone_residential?, #thermal_zone_vestibule?, #thermal_zones_get_occupancy_schedule, #true?, #validate_initial_model, #water_heater_mixed_apply_efficiency, #water_heater_mixed_apply_prm_baseline_fuel_type, #water_heater_mixed_find_capacity, #zone_hvac_component_apply_prm_baseline_fan_power, #zone_hvac_component_apply_standard_controls, #zone_hvac_component_apply_vestibule_heating_control, #zone_hvac_component_prm_baseline_fan_efficacy, #zone_hvac_component_vestibule_heating_control_required?
Methods included from PrototypeFan
apply_base_fan_variables, #create_fan_by_name, #get_fan_from_standards, #prototype_fan_apply_prototype_fan_efficiency
Methods included from CoilDX
#coil_dx_find_search_criteria, #coil_dx_heat_pump?, #coil_dx_heating_type, #coil_dx_subcategory
Methods included from CoolingTower
#cooling_tower_apply_minimum_power_per_flow, #cooling_tower_apply_minimum_power_per_flow_gpm_limit
Methods included from Pump
#pump_apply_prm_pressure_rise_and_motor_efficiency, #pump_apply_standard_minimum_motor_efficiency, #pump_brake_horsepower, #pump_motor_horsepower, #pump_pumppower, #pump_rated_w_per_gpm, #pump_standard_minimum_motor_efficiency_and_size
Methods included from Fan
#fan_adjust_pressure_rise_to_meet_fan_power, #fan_apply_standard_minimum_motor_efficiency, #fan_baseline_impeller_efficiency, #fan_brake_horsepower, #fan_change_impeller_efficiency, #fan_change_motor_efficiency, #fan_fanpower, #fan_motor_horsepower, #fan_rated_w_per_cfm, #fan_small_fan?, #fan_standard_minimum_motor_efficiency_and_size
Constructor Details
#initialize ⇒ NRELZNEReady2017MidriseApartment
Returns a new instance of NRELZNEReady2017MidriseApartment.
16442 16443 16444 16445 16446 16447 16448 16449 16450 16451 16452 16453 16454 16455 16456 16457 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16442 def initialize super() @instvarbuilding_type = @@building_type @prototype_input = self.standards_lookup_table_first(table_name: 'prototype_inputs',search_criteria: {'template' => @template,'building_type' => @@building_type }) if @prototype_input.nil? OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Model', "Could not find prototype inputs for #{{'template' => @template,'building_type' => @@building_type }}, cannot create model.") raise("Could not find prototype inputs for NRELZNEReady2017MidriseApartment, cannot create model.") return false end @lookup_building_type = self.model_get_lookup_name(@@building_type) #ideally we should map the data required to a instance variable. @geometry_file = 'geometry/' + @prototype_input['geometry_osm'] hvac_map_file = 'geometry/' + @prototype_input['hvac_json'] @system_to_space_map = load_hvac_map(hvac_map_file) self.set_variables() end |
Instance Attribute Details
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
16440 16441 16442 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16440 def building_story_map @building_story_map end |
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
16439 16440 16441 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16439 def geometry_file @geometry_file end |
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
16437 16438 16439 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16437 def lookup_building_type @lookup_building_type end |
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
16435 16436 16437 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16435 def prototype_database @prototype_database end |
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
16436 16437 16438 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16436 def prototype_input @prototype_input end |
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
16438 16439 16440 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16438 def space_type_map @space_type_map end |
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
16441 16442 16443 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16441 def system_to_space_map @system_to_space_map end |
Instance Method Details
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
16482 16483 16484 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16482 def define_building_story_map(building_type, climate_zone) return @building_story_map end |
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
16476 16477 16478 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16476 def define_hvac_system_map(building_type, climate_zone) return @system_to_space_map end |
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
16470 16471 16472 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16470 def define_space_type_map(building_type, climate_zone) return @space_type_map end |
#model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Bool
Makes changes to the daylighting sensors that are too specific to be coded generically.
16531 16532 16533 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16531 def model_custom_daylighting_tweaks(building_type, climate_zone, prototype_input, model) return true end |
#model_get_lookup_name(building_type) ⇒ String
Unify the lookup names and eliminate this method
Get the name of the building type used in lookups
16502 16503 16504 16505 16506 16507 16508 16509 16510 16511 16512 16513 16514 16515 16516 16517 16518 16519 16520 16521 16522 16523 16524 16525 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16502 def model_get_lookup_name(building_type) lookup_name = building_type case building_type when 'SmallOffice' lookup_name = 'Office' when 'MediumOffice' lookup_name = 'Office' when 'LargeOffice' lookup_name = 'Office' when 'SmallOfficeDetailed' lookup_name = 'Office' when 'MediumOfficeDetailed' lookup_name = 'Office' when 'LargeOfficeDetailed' lookup_name = 'Office' when 'RetailStandalone' lookup_name = 'Retail' when 'RetailStripmall' lookup_name = 'StripMall' when 'Office' lookup_name = 'Office' end return lookup_name end |
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard
16486 16487 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16486 def model_modify_oa_controller(model) end |
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard
16489 16490 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16489 def model_reset_or_room_vav_minimum_damper(prototype_input, model) end |
#model_update_exhaust_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
16492 16493 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16492 def model_update_exhaust_fan_efficiency(model) end |
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
16495 16496 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16495 def model_update_fan_efficiency(model) end |
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb. Each building type has its own set of methods that change things which are not common across all prototype buildings, even within a given Standard.
16462 16463 16464 16465 16466 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 16462 def set_variables() # Will be overwritten in class reopen file. # add all building methods for now. self.extend(MidriseApartment) unless @template == 'NECB 2011' end |