Class: DOERefPre1980Warehouse
- Inherits:
-
DOERefPre1980
- Object
- Standard
- ASHRAE901
- DOERefPre1980
- DOERefPre1980Warehouse
- Defined in:
- lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb
Overview
This class represents a prototypical DOERefPre1980 Warehouse.
Constant Summary collapse
- @@building_type =
"Warehouse"
Constants inherited from Standard
Instance Attribute Summary collapse
-
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
-
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
-
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
-
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
-
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
-
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
-
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
Attributes inherited from DOERefPre1980
Attributes inherited from Standard
#space_multiplier_map, #standards_data, #template
Instance Method Summary collapse
-
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
-
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
-
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
-
#initialize ⇒ DOERefPre1980Warehouse
constructor
A new instance of DOERefPre1980Warehouse.
-
#model_get_lookup_name(building_type) ⇒ String
Get the name of the building type used in lookups.
-
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_exhaust_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb.
Methods inherited from DOERefPre1980
#air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_vav_damper_action, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #coil_heating_gas_apply_prototype_efficiency, #model_add_elevator, #model_apply_infiltration_standard, #model_elevator_lift_power, #model_get_climate_zone_set_from_list, #model_swh_pump_type, #model_walkin_freezer_latent_case_credit_curve, #plant_loop_supply_water_temperature_reset_required?
Methods inherited from ASHRAE901
#fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit
Methods inherited from Standard
#adjust_infiltration_to_lower_pressure, #adjust_infiltration_to_prototype_building_conditions, #afue_to_thermal_eff, #air_loop_hvac_add_motorized_oa_damper, #air_loop_hvac_adjust_minimum_vav_damper_positions, #air_loop_hvac_adjust_minimum_vav_damper_positions_outpatient, #air_loop_hvac_allowable_system_brake_horsepower, #air_loop_hvac_apply_baseline_fan_pressure_rise, #air_loop_hvac_apply_economizer_integration, #air_loop_hvac_apply_economizer_limits, #air_loop_hvac_apply_energy_recovery_ventilator, #air_loop_hvac_apply_maximum_reheat_temperature, #air_loop_hvac_apply_minimum_vav_damper_positions, #air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_apply_prm_baseline_controls, #air_loop_hvac_apply_prm_baseline_economizer, #air_loop_hvac_apply_prm_baseline_fan_power, #air_loop_hvac_apply_prm_sizing_temperatures, #air_loop_hvac_apply_single_zone_controls, #air_loop_hvac_apply_standard_controls, #air_loop_hvac_apply_vav_damper_action, #air_loop_hvac_data_center_area_served, #air_loop_hvac_dcv_required_when_erv, #air_loop_hvac_demand_control_ventilation_limits, #air_loop_hvac_demand_control_ventilation_required?, #air_loop_hvac_disable_multizone_vav_optimization, #air_loop_hvac_dx_cooling?, #air_loop_hvac_economizer?, #air_loop_hvac_economizer_limits, #air_loop_hvac_economizer_required?, #air_loop_hvac_economizer_type_allowable?, #air_loop_hvac_enable_demand_control_ventilation, #air_loop_hvac_enable_multizone_vav_optimization, #air_loop_hvac_enable_supply_air_temperature_reset_delta, #air_loop_hvac_enable_supply_air_temperature_reset_outdoor_temperature, #air_loop_hvac_enable_supply_air_temperature_reset_warmest_zone, #air_loop_hvac_enable_unoccupied_fan_shutoff, #air_loop_hvac_energy_recovery?, #air_loop_hvac_energy_recovery_ventilator_flow_limit, #air_loop_hvac_energy_recovery_ventilator_required?, #air_loop_hvac_fan_power_limitation_pressure_drop_adjustment_brake_horsepower, #air_loop_hvac_find_design_supply_air_flow_rate, #air_loop_hvac_floor_area_served, #air_loop_hvac_floor_area_served_exterior_zones, #air_loop_hvac_floor_area_served_interior_zones, #air_loop_hvac_get_occupancy_schedule, #air_loop_hvac_integrated_economizer_required?, #air_loop_hvac_motorized_oa_damper_limits, #air_loop_hvac_motorized_oa_damper_required?, #air_loop_hvac_multi_stage_dx_cooling?, #air_loop_hvac_multizone_vav_optimization_required?, #air_loop_hvac_multizone_vav_system?, #air_loop_hvac_prm_baseline_economizer_required?, #air_loop_hvac_prm_economizer_type_and_limits, #air_loop_hvac_remove_motorized_oa_damper, #air_loop_hvac_single_zone_controls_num_stages, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_supply_air_temperature_reset_required?, #air_loop_hvac_supply_return_exhaust_relief_fans, #air_loop_hvac_system_fan_brake_horsepower, #air_loop_hvac_system_multiplier, #air_loop_hvac_terminal_reheat?, #air_loop_hvac_total_cooling_capacity, #air_loop_hvac_unoccupied_fan_shutoff_required?, #air_loop_hvac_vav_damper_action, #air_loop_hvac_vav_system?, #air_terminal_single_duct_parallel_piu_reheat_apply_prm_baseline_fan_power, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #air_terminal_single_duct_vav_reheat_apply_minimum_damper_position, #air_terminal_single_duct_vav_reheat_minimum_damper_position, #air_terminal_single_duct_vav_reheat_reheat_type, #air_terminal_single_duct_vav_reheat_set_heating_cap, #boiler_hot_water_apply_efficiency_and_curves, #boiler_hot_water_find_capacity, #boiler_hot_water_find_search_criteria, #boiler_hot_water_standard_minimum_thermal_efficiency, build, #building_story_floor_multiplier, #building_story_minimum_z_value, #chiller_electric_eir_apply_efficiency_and_curves, #chiller_electric_eir_find_capacity, #chiller_electric_eir_find_search_criteria, #chiller_electric_eir_standard_minimum_full_load_efficiency, #coil_cooling_dx_multi_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_find_capacity, #coil_cooling_dx_single_speed_standard_minimum_cop, #coil_cooling_dx_two_speed_apply_efficiency_and_curves, #coil_cooling_dx_two_speed_find_capacity, #coil_cooling_dx_two_speed_standard_minimum_cop, #coil_heating_dx_multi_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_find_capacity, #coil_heating_dx_single_speed_standard_minimum_cop, #coil_heating_gas_apply_prototype_efficiency, #coil_heating_gas_multi_stage_apply_efficiency_and_curves, #combustion_eff_to_thermal_eff, #construction_calculated_solar_heat_gain_coefficient, #construction_calculated_u_factor, #construction_calculated_visible_transmittance, #construction_set_glazing_shgc, #construction_set_glazing_u_value, #construction_set_slab_f_factor, #construction_set_u_value, #construction_set_underground_wall_c_factor, #construction_simple_glazing?, #controller_water_coil_set_convergence_limits, #convert_curve_biquadratic, #cooling_tower_single_speed_apply_efficiency_and_curves, #cooling_tower_two_speed_apply_efficiency_and_curves, #cooling_tower_variable_speed_apply_efficiency_and_curves, #cop_heating_to_cop_heating_no_fan, #cop_to_eer, #cop_to_kw_per_ton, #cop_to_seer, #create_curve_bicubic, #create_curve_biquadratic, #create_curve_cubic, #create_curve_exponent, #create_curve_quadratic, #define_space_multiplier, #eer_to_cop, #fan_constant_volume_airloop_fan_pressure_rise, #fan_constant_volume_apply_prototype_fan_pressure_rise, #fan_on_off_airloop_or_unitary_fan_pressure_rise, #fan_on_off_apply_prototype_fan_pressure_rise, #fan_variable_volume_airloop_fan_pressure_rise, #fan_variable_volume_apply_prototype_fan_pressure_rise, #fan_variable_volume_cooling_system_type, #fan_variable_volume_part_load_fan_power_limitation?, #fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #fan_variable_volume_set_control_type, #fan_zone_exhaust_apply_prototype_fan_pressure_rise, #film_coefficients_r_value, #headered_pumps_variable_speed_set_control_type, #heat_exchanger_air_to_air_sensible_and_latent_apply_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_nominal_electric_power, #heat_exchanger_air_to_air_sensible_and_latent_minimum_efficiency, #heating_design_outdoor_temperatures, #hspf_to_cop_heating_no_fan, #intialize, #kw_per_ton_to_cop, #load_hvac_map, #load_standards_database, #model_add_baseboard, #model_add_booster_swh_end_uses, #model_add_cav, #model_add_central_air_source_heat_pump, #model_add_chw_loop, #model_add_constant_schedule_ruleset, #model_add_construction, #model_add_construction_set, #model_add_curve, #model_add_cw_loop, #model_add_data_center_hvac, #model_add_data_center_load, #model_add_daylighting_controls, #model_add_design_days_and_weather_file, #model_add_district_ambient_loop, #model_add_doas, #model_add_elevator, #model_add_elevators, #model_add_evap_cooler, #model_add_exhaust_fan, #model_add_four_pipe_fan_coil, #model_add_furnace_central_ac, #model_add_ground_hx_loop, #model_add_ground_temperatures, #model_add_high_temp_radiant, #model_add_hp_loop, #model_add_hvac, #model_add_hvac_system, #model_add_hw_loop, #model_add_ideal_air_loads, #model_add_material, #model_add_prm_baseline_system, #model_add_prm_construction_set, #model_add_psz_ac, #model_add_psz_vav, #model_add_ptac, #model_add_pthp, #model_add_pvav, #model_add_pvav_pfp_boxes, #model_add_refrigeration, #model_add_refrigeration_case, #model_add_refrigeration_compressor, #model_add_refrigeration_system, #model_add_refrigeration_walkin, #model_add_schedule, #model_add_split_ac, #model_add_swh, #model_add_swh_booster, #model_add_swh_end_uses, #model_add_swh_end_uses_by_space, #model_add_swh_loop, #model_add_typical_exterior_lights, #model_add_typical_swh, #model_add_unitheater, #model_add_vav_pfp_boxes, #model_add_vav_reheat, #model_add_water_heater, #model_add_water_source_hp, #model_add_window_ac, #model_add_zone_erv, #model_add_zone_ventilation, #model_apply_hvac_efficiency_standard, #model_apply_infiltration_standard, #model_apply_multizone_vav_outdoor_air_sizing, #model_apply_prm_baseline_skylight_to_roof_ratio, #model_apply_prm_baseline_window_to_wall_ratio, #model_apply_prm_construction_types, #model_apply_prm_sizing_parameters, #model_apply_standard_constructions, #model_assign_spaces_to_stories, #model_attach_water_fixtures_to_spaces?, #model_baseline_system_vav_fan_type, #model_create_exterior_lighting_area_length_count_hash, #model_create_prm_baseline_building, #model_create_prm_baseline_building_requires_vlt_sizing_run, #model_create_space_type_hash, #model_create_story_hash, #model_cw_loop_cooling_tower_fan_type, #model_differentiate_primary_secondary_thermal_zones, #model_effective_num_stories, #model_elevator_fan_pwr, #model_elevator_lift_power, #model_elevator_lighting_pct_incandescent, #model_eliminate_outlier_zones, #model_find_and_add_construction, #model_find_ashrae_hot_water_demand, #model_find_climate_zone_set, #model_find_constructions, #model_find_icc_iecc_2015_hot_water_demand, #model_find_icc_iecc_2015_internal_loads, #model_find_object, #model_find_objects, #model_find_prototype_floor_area, #model_find_target_eui, #model_find_target_eui_by_end_use, #model_find_water_heater_capacity_volume_and_parasitic, #model_get_baseline_system_type_by_zone, #model_get_building_climate_zone_and_building_type, #model_get_climate_zone_set_from_list, #model_get_construction_properties, #model_get_full_weather_file_path, #model_get_or_add_ambient_water_loop, #model_get_or_add_chilled_water_loop, #model_get_or_add_ground_hx_loop, #model_get_or_add_heat_pump_loop, #model_get_or_add_hot_water_loop, #model_get_story_for_nominal_z_coordinate, #model_group_zones_by_story, #model_make_name, #model_num_stories_spanned, #model_prm_baseline_system_change_fuel_type, #model_prm_baseline_system_group_minimum_area, #model_prm_baseline_system_groups, #model_prm_baseline_system_number, #model_prm_baseline_system_type, #model_prm_skylight_to_roof_ratio_limit, #model_process_results_for_datapoint, #model_remap_office, #model_remove_external_shading_devices, #model_remove_prm_hvac, #model_residential_and_nonresidential_floor_areas, #model_swh_pump_type, #model_typical_hvac_system_type, #model_validate_standards_spacetypes_in_model, #model_walkin_freezer_latent_case_credit_curve, #model_zones_with_occ_and_fuel_type, #planar_surface_apply_standard_construction, #plant_loop_apply_prm_baseline_chilled_water_pumping_type, #plant_loop_apply_prm_baseline_chilled_water_temperatures, #plant_loop_apply_prm_baseline_condenser_water_pumping_type, #plant_loop_apply_prm_baseline_condenser_water_temperatures, #plant_loop_apply_prm_baseline_hot_water_pumping_type, #plant_loop_apply_prm_baseline_hot_water_temperatures, #plant_loop_apply_prm_baseline_pump_power, #plant_loop_apply_prm_baseline_pumping_type, #plant_loop_apply_prm_baseline_temperatures, #plant_loop_apply_prm_number_of_boilers, #plant_loop_apply_prm_number_of_chillers, #plant_loop_apply_prm_number_of_cooling_towers, #plant_loop_apply_standard_controls, #plant_loop_enable_supply_water_temperature_reset, #plant_loop_find_maximum_loop_flow_rate, #plant_loop_prm_baseline_condenser_water_temperatures, #plant_loop_supply_water_temperature_reset_required?, #plant_loop_swh_loop?, #plant_loop_swh_system_type, #plant_loop_total_cooling_capacity, #plant_loop_total_floor_area_served, #plant_loop_total_heating_capacity, #plant_loop_total_rated_w_per_gpm, #plant_loop_variable_flow_system?, #pump_variable_speed_set_control_type, register_standard, #safe_load_model, #safe_load_sql, #schedule_compact_annual_min_max_value, #schedule_constant_annual_equivalent_full_load_hrs, #schedule_constant_annual_min_max_value, #schedule_ruleset_annual_equivalent_full_load_hrs, #schedule_ruleset_annual_hours_above_value, #schedule_ruleset_annual_min_max_value, #seer_to_cop_cooling_no_fan, #space_add_daylighting_controls, #space_apply_infiltration_rate, #space_conditioning_category, #space_cooled?, #space_daylighted_area_window_width, #space_daylighted_areas, #space_daylighting_control_required?, #space_daylighting_fractions_and_windows, #space_design_internal_load, #space_exterior_wall_and_roof_and_subsurface_area, #space_exterior_wall_and_window_area, #space_get_adjacent_space_with_most_shared_wall_area, #space_get_adjacent_spaces_with_shared_wall_areas, #space_heated?, #space_infiltration_rate_75_pa, #space_plenum?, #space_residential?, #space_sidelighting_effective_aperture, #space_skylight_effective_aperture, #space_type_apply_internal_load_schedules, #space_type_apply_internal_loads, #space_type_apply_rendering_color, #space_type_get_construction_properties, #space_type_get_standards_data, #strip_model, #sub_surface_component_infiltration_rate, #sub_surface_reduce_area_by_percent_by_raising_sill, #sub_surface_reduce_area_by_percent_by_shrinking_toward_centroid, #sub_surface_vertical_rectangle?, #surface_component_infiltration_rate, #thermal_eff_to_afue, #thermal_eff_to_comb_eff, #thermal_zone_add_exhaust, #thermal_zone_add_exhaust_fan_dcv, #thermal_zone_add_unconditioned_thermostat, #thermal_zone_apply_prm_baseline_supply_temperatures, #thermal_zone_conditioning_category, #thermal_zone_convert_oa_req_to_per_area, #thermal_zone_cooled?, #thermal_zone_demand_control_ventilation_limits, #thermal_zone_demand_control_ventilation_required?, #thermal_zone_design_internal_load, #thermal_zone_exhaust_fan_dcv_required?, #thermal_zone_floor_area_with_zone_multipliers, #thermal_zone_fossil_hybrid_or_purchased_heat?, #thermal_zone_fossil_or_electric_type, #thermal_zone_get_adjacent_zones_with_shared_wall_areas, #thermal_zone_get_occupancy_schedule, #thermal_zone_heated?, #thermal_zone_infer_system_type, #thermal_zone_majority_space_type, #thermal_zone_mixed_heating_fuel?, #thermal_zone_occupancy_type, #thermal_zone_outdoor_airflow_rate, #thermal_zone_outdoor_airflow_rate_per_area, #thermal_zone_plenum?, #thermal_zone_prm_baseline_cooling_design_supply_temperature, #thermal_zone_prm_baseline_heating_design_supply_temperature, #thermal_zone_residential?, #water_heater_mixed_apply_efficiency, #water_heater_mixed_apply_prm_baseline_fuel_type, #water_heater_mixed_find_capacity, #zone_hvac_component_apply_prm_baseline_fan_power
Methods included from PrototypeFan
#prototype_fan_apply_prototype_fan_efficiency
Methods included from CoilDX
#coil_dx_find_search_criteria, #coil_dx_heat_pump?, #coil_dx_heating_type, #coil_dx_subcategory
Methods included from CoolingTower
#cooling_tower_apply_minimum_power_per_flow, #cooling_tower_apply_minimum_power_per_flow_gpm_limit
Methods included from Pump
#pump_apply_prm_pressure_rise_and_motor_efficiency, #pump_apply_standard_minimum_motor_efficiency, #pump_brake_horsepower, #pump_motor_horsepower, #pump_pumppower, #pump_rated_w_per_gpm, #pump_standard_minimum_motor_efficiency_and_size
Methods included from Fan
#fan_adjust_pressure_rise_to_meet_fan_power, #fan_apply_standard_minimum_motor_efficiency, #fan_baseline_impeller_efficiency, #fan_brake_horsepower, #fan_change_impeller_efficiency, #fan_change_motor_efficiency, #fan_fanpower, #fan_motor_horsepower, #fan_rated_w_per_cfm, #fan_small_fan?, #fan_standard_minimum_motor_efficiency_and_size
Constructor Details
#initialize ⇒ DOERefPre1980Warehouse
Returns a new instance of DOERefPre1980Warehouse.
9355 9356 9357 9358 9359 9360 9361 9362 9363 9364 9365 9366 9367 9368 9369 9370 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9355 def initialize super() @instvarbuilding_type = @@building_type @prototype_input = self.model_find_object(@standards_data['prototype_inputs'], {'template' => @template,'building_type' => @@building_type }, nil) if @prototype_input.nil? OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Model', "Could not find prototype inputs for #{{'template' => @template,'building_type' => @@building_type }}, cannot create model.") raise("Could not find prototype inputs for DOERefPre1980Warehouse, cannot create model.") return false end @lookup_building_type = self.model_get_lookup_name(@@building_type) #ideally we should map the data required to a instance variable. @geometry_file = 'geometry/' + self.class.name + '.osm' hvac_map_file = 'geometry/' + self.class.name + '.hvac_map.json' @system_to_space_map = load_hvac_map(hvac_map_file) self.set_variables() end |
Instance Attribute Details
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
9353 9354 9355 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9353 def building_story_map @building_story_map end |
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
9352 9353 9354 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9352 def geometry_file @geometry_file end |
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
9350 9351 9352 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9350 def lookup_building_type @lookup_building_type end |
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
9348 9349 9350 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9348 def prototype_database @prototype_database end |
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
9349 9350 9351 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9349 def prototype_input @prototype_input end |
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
9351 9352 9353 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9351 def space_type_map @space_type_map end |
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
9354 9355 9356 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9354 def system_to_space_map @system_to_space_map end |
Instance Method Details
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
9395 9396 9397 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9395 def define_building_story_map(building_type, climate_zone) return @building_story_map end |
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
9389 9390 9391 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9389 def define_hvac_system_map(building_type, climate_zone) return @system_to_space_map end |
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
9383 9384 9385 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9383 def define_space_type_map(building_type, climate_zone) return @space_type_map end |
#model_get_lookup_name(building_type) ⇒ String
Unify the lookup names and eliminate this method
Get the name of the building type used in lookups
9415 9416 9417 9418 9419 9420 9421 9422 9423 9424 9425 9426 9427 9428 9429 9430 9431 9432 9433 9434 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9415 def model_get_lookup_name(building_type) lookup_name = building_type case building_type when 'SmallOffice' lookup_name = 'Office' when 'MediumOffice' lookup_name = 'Office' when 'LargeOffice' lookup_name = 'Office' when 'LargeOfficeDetail' lookup_name = 'Office' when 'RetailStandalone' lookup_name = 'Retail' when 'RetailStripmall' lookup_name = 'StripMall' when 'Office' lookup_name = 'Office' end return lookup_name end |
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard
9399 9400 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9399 def model_modify_oa_controller(model) end |
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard
9402 9403 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9402 def model_reset_or_room_vav_minimum_damper(prototype_input, model) end |
#model_update_exhaust_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
9405 9406 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9405 def model_update_exhaust_fan_efficiency(model) end |
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
9408 9409 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9408 def model_update_fan_efficiency(model) end |
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb. Each building type has its own set of methods that change things which are not common across all prototype buildings, even within a given Standard.
9375 9376 9377 9378 9379 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 9375 def set_variables() # Will be overwritten in class reopen file. # add all building methods for now. self.extend(Warehouse) unless @template == 'NECB 2011' end |