Module: HighriseApartment
- Defined in:
- lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb
Overview
Custom changes for the HighriseApartment prototype. These are changes that are inconsistent with other prototype building types.
Instance Method Summary collapse
-
#add_door_infiltration(climate_zone, model) ⇒ Object
add extra infiltration for ground floor corridor.
-
#add_extra_equip_corridor(model) ⇒ Object
add elevator and lights&fans for the top floor corridor.
- #model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object
- #model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object
- #model_update_fan_efficiency(model) ⇒ Object
- #update_waterheater_loss_coefficient(model) ⇒ Object
Instance Method Details
#add_door_infiltration(climate_zone, model) ⇒ Object
add extra infiltration for ground floor corridor
66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 66 def add_door_infiltration(climate_zone, model) g_corridor = model.getSpaceByName('G Corridor').get infiltration_g_corridor_door = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model) infiltration_g_corridor_door.setName('G Corridor door Infiltration') infiltration_g_corridor_door.setSpace(g_corridor) case template when '90.1-2004' infiltration_g_corridor_door.setDesignFlowRate(1.523916863) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.144')) when '90.1-2007', '90.1-2010', '90.1-2013' case climate_zone when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-2B' infiltration_g_corridor_door.setDesignFlowRate(1.523916863) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.144')) else infiltration_g_corridor_door.setDesignFlowRate(1.008078792) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.131')) end end end |
#add_extra_equip_corridor(model) ⇒ Object
add elevator and lights&fans for the top floor corridor
18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 18 def add_extra_equip_corridor(model) corridor_top_space = model.getSpaceByName('T Corridor').get elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def1.setName('T Corridor Electric Equipment Definition1') elec_equip_def2.setName('T Corridor Electric Equipment Definition2') elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0) elec_equip_def1.setFractionLost(0.95) elec_equip_def2.setFractionLatent(0) elec_equip_def2.setFractionRadiant(0) elec_equip_def2.setFractionLost(0.95) elec_equip_def1.setDesignLevel(20_370) case template when '90.1-2013' elec_equip_def2.setDesignLevel(63) when '90.1-2010' elec_equip_def2.setDesignLevel(105.9) when '90.1-2004', '90.1-2007' elec_equip_def2.setDesignLevel(161.9) end # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2) elec_equip1.setName('T Corridor_Elevators_Equip') elec_equip2.setName('Elevators_Lights_Fan') elec_equip1.setSpace(corridor_top_space) elec_equip2.setSpace(corridor_top_space) elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS')) case template when '90.1-2004', '90.1-2007' elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_24_7')) when '90.1-2010', '90.1-2013' elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_ADD_DF')) end end |
#model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object
6 7 8 9 10 11 12 13 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 6 def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) # add elevator and lights&fans for the ground floor corridor add_extra_equip_corridor(model) # add extra infiltration for ground floor corridor add_door_infiltration(climate_zone, model) return true end |
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object
94 95 96 97 98 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 94 def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) update_waterheater_loss_coefficient(model) return true end |
#model_update_fan_efficiency(model) ⇒ Object
87 88 89 90 91 92 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 87 def model_update_fan_efficiency(model) model.getFanOnOffs.sort.each do |fan_onoff| fan_onoff.setFanEfficiency(0.53625) fan_onoff.setMotorEfficiency(0.825) end end |
#update_waterheater_loss_coefficient(model) ⇒ Object
55 56 57 58 59 60 61 62 63 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 55 def update_waterheater_loss_coefficient(model) case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013' model.getWaterHeaterMixeds.sort.each do |water_heater| water_heater.setOffCycleLossCoefficienttoAmbientTemperature(46.288874618) water_heater.setOnCycleLossCoefficienttoAmbientTemperature(46.288874618) end end end |