Module: MediumOffice
- Defined in:
- lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb
Overview
Custom changes for the MediumOffice prototype. These are changes that are inconsistent with other prototype building types.
Instance Method Summary collapse
-
#add_door_infiltration(climate_zone, model) ⇒ Object
add hvac.
- #model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object
- #model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object
- #update_waterheater_loss_coefficient(model) ⇒ Object
Instance Method Details
#add_door_infiltration(climate_zone, model) ⇒ Object
add hvac
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb', line 33 def add_door_infiltration(climate_zone, model) # add extra infiltration for entry door in m3/s (there is no attic in 'DOE Ref Pre-1980') unless template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980' entry_space = model.getSpaceByName('Perimeter_bot_ZN_1').get infiltration_entrydoor = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model) infiltration_entrydoor.setName('entry door Infiltration') infiltration_per_zone_entrydoor = 0 if template == '90.1-2004' infiltration_per_zone_entrydoor = 1.04300287 infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH')) elsif template == '90.1-2007' || template == '90.1-2010' || template == '90.1-2013' case climate_zone when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-1B', 'ASHRAE 169-2006-2B' infiltration_per_zone_entrydoor = 1.04300287 infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH')) else infiltration_per_zone_entrydoor = 0.678659786 infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH')) end end infiltration_entrydoor.setDesignFlowRate(infiltration_per_zone_entrydoor) infiltration_entrydoor.setSpace(entry_space) end end |
#model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb', line 6 def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments') model.getSpaces.sort.each do |space| if space.name.get.to_s == 'Core_bottom' model_add_elevator(model, space, prototype_input['number_of_elevators'], prototype_input['elevator_type'], prototype_input['elevator_schedule'], prototype_input['elevator_fan_schedule'], prototype_input['elevator_fan_schedule'], building_type) end end OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished building type specific adjustments') # add extra infiltration for entry door add_door_infiltration(climate_zone, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Added door infiltration') return true end |
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object
68 69 70 71 72 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb', line 68 def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) update_waterheater_loss_coefficient(model) return true end |
#update_waterheater_loss_coefficient(model) ⇒ Object
58 59 60 61 62 63 64 65 66 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb', line 58 def update_waterheater_loss_coefficient(model) case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', 'NECB2011' model.getWaterHeaterMixeds.sort.each do |water_heater| water_heater.setOffCycleLossCoefficienttoAmbientTemperature(7.561562668) water_heater.setOnCycleLossCoefficienttoAmbientTemperature(7.561562668) end end end |