Module: MidriseApartment
- Defined in:
- lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb
Overview
Custom changes for the MidriseApartment prototype. These are changes that are inconsistent with other prototype building types.
Instance Method Summary collapse
-
#add_door_infiltration(climate_zone, model) ⇒ Object
add extra infiltration for ground floor corridor.
-
#add_extra_equip_corridor(model) ⇒ Object
add elevator and lights&fans for the ground floor corridor.
- #adjust_clg_setpoint(climate_zone, model) ⇒ Object
- #model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object
- #model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object
- #update_waterheater_loss_coefficient(model) ⇒ Object
Instance Method Details
#add_door_infiltration(climate_zone, model) ⇒ Object
add extra infiltration for ground floor corridor
96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 96 def add_door_infiltration(climate_zone, model) case template when 'DOE Ref 1980-2004', 'DOE Ref Pre-1980' # no door infiltration in these two vintages when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013' g_corridor = model.getSpaceByName('G Corridor').get infiltration_g_corridor_door = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model) infiltration_g_corridor_door.setName('G Corridor door Infiltration') infiltration_g_corridor_door.setSpace(g_corridor) case template when '90.1-2004' infiltration_g_corridor_door.setDesignFlowRate(0.520557541) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2004_2007')) when '90.1-2007' case climate_zone when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-2B' infiltration_g_corridor_door.setDesignFlowRate(0.520557541) else infiltration_g_corridor_door.setDesignFlowRate(0.327531218) end infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2004_2007')) when '90.1-2010', '90.1-2013' case climate_zone when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-2B' infiltration_g_corridor_door.setDesignFlowRate(0.520557541) else infiltration_g_corridor_door.setDesignFlowRate(0.327531218) end infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2010_2013')) end end end |
#add_extra_equip_corridor(model) ⇒ Object
add elevator and lights&fans for the ground floor corridor
36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 36 def add_extra_equip_corridor(model) corridor_ground_space = model.getSpaceByName('G Corridor').get elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def1.setName('Ground Corridor Electric Equipment Definition1') elec_equip_def2.setName('Ground Corridor Electric Equipment Definition2') case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013' elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0) elec_equip_def1.setFractionLost(0.95) elec_equip_def2.setFractionLatent(0) elec_equip_def2.setFractionRadiant(0) elec_equip_def2.setFractionLost(0.95) elec_equip_def1.setDesignLevel(16_055) if template == '90.1-2013' elec_equip_def2.setDesignLevel(63) elsif template == '90.1-2010' elec_equip_def2.setDesignLevel(105.9) else elec_equip_def2.setDesignLevel(161.9) end # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2) elec_equip1.setName('G Corridor_Elevators_Equip') elec_equip2.setName('Elevators_Lights_Fan') elec_equip1.setSpace(corridor_ground_space) elec_equip2.setSpace(corridor_ground_space) elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS')) case template when '90.1-2004', '90.1-2007' elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_24_7')) when '90.1-2010', '90.1-2013' elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_ADD_DF')) end when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004' elec_equip_def1.setDesignLevel(16_055) elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0) elec_equip_def1.setFractionLost(0.95) # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip1.setName('G Corridor_Elevators_Equip') elec_equip1.setSpace(corridor_ground_space) elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS Pre2004')) end end |
#adjust_clg_setpoint(climate_zone, model) ⇒ Object
21 22 23 24 25 26 27 28 29 30 31 32 33 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 21 def adjust_clg_setpoint(climate_zone, model) space_name = 'Office' space_type_name = model.getSpaceByName(space_name).get.spaceType.get.name.get thermostat_name = space_type_name + ' Thermostat' thermostat = model.getThermostatSetpointDualSetpointByName(thermostat_name).get case template when '90.1-2004', '90.1-2007', '90.1-2010' case climate_zone when 'ASHRAE 169-2006-2B', 'ASHRAE 169-2006-1B', 'ASHRAE 169-2006-3B' thermostat.setCoolingSetpointTemperatureSchedule(model_add_schedule(model, 'ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM')) end end end |
#model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) ⇒ Object
6 7 8 9 10 11 12 13 14 15 16 17 18 19 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 6 def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments') # adjust the cooling setpoint adjust_clg_setpoint(climate_zone, model) # add elevator and lights&fans for the ground floor corridor add_extra_equip_corridor(model) # add extra infiltration for ground floor corridor add_door_infiltration(climate_zone, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished building type specific adjustments') return true end |
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Object
129 130 131 132 133 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 129 def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) update_waterheater_loss_coefficient(model) return true end |
#update_waterheater_loss_coefficient(model) ⇒ Object
85 86 87 88 89 90 91 92 93 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 85 def update_waterheater_loss_coefficient(model) case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', 'NECB2011' model.getWaterHeaterMixeds.sort.each do |water_heater| water_heater.setOffCycleLossCoefficienttoAmbientTemperature(46.288874618) water_heater.setOnCycleLossCoefficienttoAmbientTemperature(46.288874618) end end end |