Class: OpenStudio::Model::CoilHeatingWater
- Inherits:
-
Object
- Object
- OpenStudio::Model::CoilHeatingWater
- Defined in:
- lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb
Overview
open the class to add methods to return sizing values
Instance Method Summary collapse
-
#applySizingValues ⇒ Object
Takes the values calculated by the EnergyPlus sizing routines and puts them into this object model in place of the autosized fields.
-
#autosize ⇒ Object
Sets all auto-sizeable fields to autosize.
-
#autosizedMaximumWaterFlowRate ⇒ Object
returns the autosized maximum water flow rate as an optional double.
-
#autosizedRatedCapacity ⇒ Object
returns the autosized rated capacity as an optional double.
-
#autosizedUFactorTimesAreaValue ⇒ Object
returns the autosized u-factor times area value as an optional double.
Instance Method Details
#applySizingValues ⇒ Object
Takes the values calculated by the EnergyPlus sizing routines and puts them into this object model in place of the autosized fields. Must have previously completed a run with sql output for this to work.
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 |
# File 'lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb', line 13 def applySizingValues maximum_water_flow_rate = self.autosizedMaximumWaterFlowRate if maximum_water_flow_rate.is_initialized self.setMaximumWaterFlowRate(maximum_water_flow_rate.get) end u_factor_times_area_value = self.autosizedUFactorTimesAreaValue if u_factor_times_area_value.is_initialized self.setUFactorTimesAreaValue(u_factor_times_area_value.get) end rated_capacity = self.autosizedRatedCapacity if rated_capacity.is_initialized self.setRatedCapacity(rated_capacity.get) end end |
#autosize ⇒ Object
Sets all auto-sizeable fields to autosize
6 7 8 |
# File 'lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb', line 6 def autosize OpenStudio::logFree(OpenStudio::Warn, "openstudio.sizing.CoilHeatingWater", ".autosize not yet implemented for #{self.iddObject.type.valueDescription}.") end |
#autosizedMaximumWaterFlowRate ⇒ Object
returns the autosized maximum water flow rate as an optional double
33 34 35 36 37 |
# File 'lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb', line 33 def autosizedMaximumWaterFlowRate return self.model.getAutosizedValue(self, 'Design Size Maximum Water Flow Rate', 'm3/s') end |
#autosizedRatedCapacity ⇒ Object
returns the autosized rated capacity as an optional double
47 48 49 50 51 52 53 54 55 56 57 58 |
# File 'lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb', line 47 def autosizedRatedCapacity # In E+ 8.8, (OS 2.2.2 onward) the field name changed if self.model.version < OpenStudio::VersionString.new('2.2.2') field = 'Design Size Design Coil Load' else field = 'Design Size Rated Capacity' end return self.model.getAutosizedValue(self, field, 'W') end |
#autosizedUFactorTimesAreaValue ⇒ Object
returns the autosized u-factor times area value as an optional double
40 41 42 43 44 |
# File 'lib/openstudio-standards/hvac_sizing/Siz.CoilHeatingWater.rb', line 40 def autosizedUFactorTimesAreaValue return self.model.getAutosizedValue(self, 'Design Size U-Factor Times Area Value', 'W/K') end |