Module: MidriseApartment

Defined in:
lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb

Overview

Custom changes for the MidriseApartment prototype. These are changes that are inconsistent with other prototype building types.

Instance Method Summary collapse

Instance Method Details

#add_door_infiltration(climate_zone, model) ⇒ Boolean

add extra infiltration for ground floor corridor

Parameters:

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 111

def add_door_infiltration(climate_zone, model)
  return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'

  g_corridor = model.getSpaceByName('G Corridor').get
  infiltration_g_corridor_door = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
  infiltration_g_corridor_door.setName('G Corridor door Infiltration')
  infiltration_g_corridor_door.setSpace(g_corridor)
  case template
    when '90.1-2004'
      infiltration_g_corridor_door.setDesignFlowRate(0.520557541)
      infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2004_2007'))
    when '90.1-2007'
      case climate_zone
        when 'ASHRAE 169-2006-0A',
             'ASHRAE 169-2006-1A',
             'ASHRAE 169-2006-0B',
             'ASHRAE 169-2006-1B',
             'ASHRAE 169-2006-2A',
             'ASHRAE 169-2006-2B',
             'ASHRAE 169-2013-0A',
             'ASHRAE 169-2013-1A',
             'ASHRAE 169-2013-0B',
             'ASHRAE 169-2013-1B',
             'ASHRAE 169-2013-2A',
             'ASHRAE 169-2013-2B'
          infiltration_g_corridor_door.setDesignFlowRate(0.520557541)
        else
          infiltration_g_corridor_door.setDesignFlowRate(0.327531218)
      end
      infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2004_2007'))
    when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      case climate_zone
        when 'ASHRAE 169-2006-0A',
             'ASHRAE 169-2006-1A',
             'ASHRAE 169-2006-0B',
             'ASHRAE 169-2006-1B',
             'ASHRAE 169-2006-2A',
             'ASHRAE 169-2006-2B',
             'ASHRAE 169-2013-0A',
             'ASHRAE 169-2013-1A',
             'ASHRAE 169-2013-0B',
             'ASHRAE 169-2013-1B',
             'ASHRAE 169-2013-2A',
             'ASHRAE 169-2013-2B'
          infiltration_g_corridor_door.setDesignFlowRate(0.520557541)
        else
          infiltration_g_corridor_door.setDesignFlowRate(0.327531218)
      end
      infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentMidRise INFIL_Door_Opening_SCH_2010_2013'))
  end
  # Door infiltration in model not impacted by wind or temperature
  infiltration_g_corridor_door.setConstantTermCoefficient(1.0)
  infiltration_g_corridor_door.setTemperatureTermCoefficient(0.0)
  infiltration_g_corridor_door.setVelocityTermCoefficient(0.0)
  infiltration_g_corridor_door.setVelocitySquaredTermCoefficient(0.0)
  return true
end

#add_extra_equip_corridor(model) ⇒ Boolean

add elevator and lights&fans for the ground floor corridor

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 56

def add_extra_equip_corridor(model)
  corridor_ground_space = model.getSpaceByName('G Corridor').get
  elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
  elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
  elec_equip_def1.setName('Ground Corridor Electric Equipment Definition1')
  elec_equip_def2.setName('Ground Corridor Electric Equipment Definition2')
  case template
    when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      elec_equip_def1.setFractionLatent(0)
      elec_equip_def1.setFractionRadiant(0)
      elec_equip_def1.setFractionLost(0.95)
      elec_equip_def2.setFractionLatent(0)
      elec_equip_def2.setFractionRadiant(0)
      elec_equip_def2.setFractionLost(0.95)
      elec_equip_def1.setDesignLevel(16_055)
      if template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
        elec_equip_def2.setDesignLevel(63)
      elsif template == '90.1-2010'
        elec_equip_def2.setDesignLevel(105.9)
      else
        elec_equip_def2.setDesignLevel(161.9)
      end
      # Create the electric equipment instance and hook it up to the space type
      elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1)
      elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2)
      elec_equip1.setName('G Corridor_Elevators_Equip')
      elec_equip2.setName('Elevators_Lights_Fan')
      elec_equip1.setSpace(corridor_ground_space)
      elec_equip2.setSpace(corridor_ground_space)
      elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS'))
      case template
        when '90.1-2004', '90.1-2007'
          elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_24_7'))
        when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
          elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_ADD_DF'))
      end
    when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
      elec_equip_def1.setDesignLevel(16_055)
      elec_equip_def1.setFractionLatent(0)
      elec_equip_def1.setFractionRadiant(0)
      elec_equip_def1.setFractionLost(0.95)
      # Create the electric equipment instance and hook it up to the space type
      elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1)
      elec_equip1.setName('G Corridor_Elevators_Equip')
      elec_equip1.setSpace(corridor_ground_space)
      elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS Pre2004'))
  end
  return true
end

#adjust_clg_setpoint(climate_zone, model) ⇒ Boolean

adjust office cooling setpoint in specific climate zones

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 30

def adjust_clg_setpoint(climate_zone, model)
  space_name = 'Office'
  space_type_name = model.getSpaceByName(space_name).get.spaceType.get.name.get
  thermostat_name = space_type_name + ' Thermostat'
  thermostat = model.getThermostatSetpointDualSetpointByName(thermostat_name).get
  case template
    when '90.1-2004', '90.1-2007', '90.1-2010'
      case climate_zone
        when 'ASHRAE 169-2006-0B',
             'ASHRAE 169-2006-1B',
             'ASHRAE 169-2006-2B',
             'ASHRAE 169-2006-3B',
             'ASHRAE 169-2013-0B',
             'ASHRAE 169-2013-1B',
             'ASHRAE 169-2013-2B',
             'ASHRAE 169-2013-3B'
          thermostat.setCoolingSetpointTemperatureSchedule(model_add_schedule(model, 'ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM'))
      end
  end
  return true
end

#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

geometry adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String the building type)

    uilding_type [String the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



187
188
189
190
191
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 187

def model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input)
  # Set original building North axis
  OpenstudioStandards::Geometry.model_set_building_north_axis(model, 0.0)
  return true
end

#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

hvac adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String the building type)

    uilding_type [String the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



11
12
13
14
15
16
17
18
19
20
21
22
23
24
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 11

def model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input)
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments')

  # adjust the cooling setpoint
  adjust_clg_setpoint(climate_zone, model)
  # add elevator and lights&fans for the ground floor corridor
  add_extra_equip_corridor(model)
  # add extra infiltration for ground floor corridor
  add_door_infiltration(climate_zone, model)

  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished building type specific adjustments')

  return true
end

#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

swh adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String the building type)

    uilding_type [String the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



176
177
178
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb', line 176

def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
  return true
end