Module: HighriseApartment
- Defined in:
- lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb
Overview
Custom changes for the HighriseApartment prototype. These are changes that are inconsistent with other prototype building types.
Instance Method Summary collapse
-
#add_door_infiltration(climate_zone, model) ⇒ Boolean
add extra infiltration for ground floor corridor.
-
#add_extra_equip_corridor(model) ⇒ Boolean
add elevator and lights&fans for the top floor corridor.
-
#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
geometry adjustments specific to the prototype model.
-
#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
hvac adjustments specific to the prototype model.
-
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
swh adjustments specific to the prototype model.
-
#model_update_fan_efficiency(model) ⇒ Boolean
update fan efficiency.
Instance Method Details
#add_door_infiltration(climate_zone, model) ⇒ Boolean
add extra infiltration for ground floor corridor
97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 97 def add_door_infiltration(climate_zone, model) return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980' g_corridor = model.getSpaceByName('G Corridor').get infiltration_g_corridor_door = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model) infiltration_g_corridor_door.setName('G Corridor door Infiltration') infiltration_g_corridor_door.setSpace(g_corridor) case template when '90.1-2004' infiltration_g_corridor_door.setDesignFlowRate(1.523916863) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.144')) when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019' case climate_zone when 'ASHRAE 169-2006-0A', 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-2B', 'ASHRAE 169-2013-0A', 'ASHRAE 169-2013-1A', 'ASHRAE 169-2013-2A', 'ASHRAE 169-2013-2B' infiltration_g_corridor_door.setDesignFlowRate(1.523916863) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.144')) else infiltration_g_corridor_door.setDesignFlowRate(1.008078792) infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.131')) end end return true end |
#add_extra_equip_corridor(model) ⇒ Boolean
add elevator and lights&fans for the top floor corridor
54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 54 def add_extra_equip_corridor(model) corridor_top_space = model.getSpaceByName('T Corridor').get elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def1.setName('T Corridor Electric Equipment Definition1') elec_equip_def2.setName('T Corridor Electric Equipment Definition2') elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0) elec_equip_def1.setFractionLost(0.95) elec_equip_def2.setFractionLatent(0) elec_equip_def2.setFractionRadiant(0) elec_equip_def2.setFractionLost(0.95) elec_equip_def1.setDesignLevel(20_370) case template when '90.1-2013', '90.1-2016', '90.1-2019' elec_equip_def2.setDesignLevel(63) when '90.1-2010' elec_equip_def2.setDesignLevel(105.9) when '90.1-2004', '90.1-2007' elec_equip_def2.setDesignLevel(161.9) end # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2) elec_equip1.setName('T Corridor_Elevators_Equip') elec_equip2.setName('Elevators_Lights_Fan') elec_equip1.setSpace(corridor_top_space) elec_equip2.setSpace(corridor_top_space) elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS')) case template when '90.1-2004', '90.1-2007' elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_24_7')) when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019' elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_ADD_DF')) end return true end |
#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
geometry adjustments specific to the prototype model
160 161 162 163 164 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 160 def model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) # Set original building North axis OpenstudioStandards::Geometry.model_set_building_north_axis(model, 0.0) return true end |
#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
hvac adjustments specific to the prototype model
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 11 def model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific HVAC adjustments') # add elevator and lights&fans for the ground floor corridor add_extra_equip_corridor(model) # add extra infiltration for ground floor corridor add_door_infiltration(climate_zone, model) # add transformer # efficiency based on a 75 kVA transformer case template when '90.1-2004', '90.1-2007' transformer_efficiency = 0.966 when '90.1-2010', '90.1-2013' transformer_efficiency = 0.98 when '90.1-2016', '90.1-2019' transformer_efficiency = 0.986 else transformer_efficiency = nil end return true if transformer_efficiency.nil? # Change to output variable name in E+ 9.4 (OS 3.1.0) excluded_interiorequip_variable = if model.version < OpenStudio::VersionString.new('3.1.0') 'Electric Equipment Electric Energy' else 'Electric Equipment Electricity Energy' end model_add_transformer(model, wired_lighting_frac: 0.0015, transformer_size: 75000, transformer_efficiency: transformer_efficiency, excluded_interiorequip_key: 'T Corridor_Elevators_Equip', excluded_interiorequip_meter: excluded_interiorequip_variable) return true end |
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
swh adjustments specific to the prototype model
149 150 151 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 149 def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) return true end |
#model_update_fan_efficiency(model) ⇒ Boolean
update fan efficiency
132 133 134 135 136 137 138 139 140 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 132 def model_update_fan_efficiency(model) model.getFanOnOffs.sort.each do |fan_onoff| next if fan_onoff.name.get.to_s.include?('ERV') fan_onoff.setFanEfficiency(0.53625) fan_onoff.setMotorEfficiency(0.825) end return true end |