#add_door_infiltration(climate_zone, model) ⇒ Boolean

add extra infiltration for ground floor corridor

Parameters:

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 97

def add_door_infiltration(climate_zone, model)
  return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'

  g_corridor = model.getSpaceByName('G Corridor').get
  infiltration_g_corridor_door = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
  infiltration_g_corridor_door.setName('G Corridor door Infiltration')
  infiltration_g_corridor_door.setSpace(g_corridor)
  case template
    when '90.1-2004'
      infiltration_g_corridor_door.setDesignFlowRate(1.523916863)
      infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.144'))
    when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      case climate_zone
        when 'ASHRAE 169-2006-0A',
             'ASHRAE 169-2006-1A',
             'ASHRAE 169-2006-2A',
             'ASHRAE 169-2006-2B',
             'ASHRAE 169-2013-0A',
             'ASHRAE 169-2013-1A',
             'ASHRAE 169-2013-2A',
             'ASHRAE 169-2013-2B'
          infiltration_g_corridor_door.setDesignFlowRate(1.523916863)
          infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.144'))
        else
          infiltration_g_corridor_door.setDesignFlowRate(1.008078792)
          infiltration_g_corridor_door.setSchedule(model_add_schedule(model, 'ApartmentHighRise INFIL_Door_Opening_SCH_0.131'))
      end
  end
  return true
end

#add_extra_equip_corridor(model) ⇒ Boolean

add elevator and lights&fans for the top floor corridor

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 54

def add_extra_equip_corridor(model)
  corridor_top_space = model.getSpaceByName('T Corridor').get
  elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
  elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
  elec_equip_def1.setName('T Corridor Electric Equipment Definition1')
  elec_equip_def2.setName('T Corridor Electric Equipment Definition2')
  elec_equip_def1.setFractionLatent(0)
  elec_equip_def1.setFractionRadiant(0)
  elec_equip_def1.setFractionLost(0.95)
  elec_equip_def2.setFractionLatent(0)
  elec_equip_def2.setFractionRadiant(0)
  elec_equip_def2.setFractionLost(0.95)
  elec_equip_def1.setDesignLevel(20_370)
  case template
    when '90.1-2013', '90.1-2016', '90.1-2019'
      elec_equip_def2.setDesignLevel(63)
    when '90.1-2010'
      elec_equip_def2.setDesignLevel(105.9)
    when '90.1-2004', '90.1-2007'
      elec_equip_def2.setDesignLevel(161.9)
  end
  # Create the electric equipment instance and hook it up to the space type
  elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1)
  elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2)
  elec_equip1.setName('T Corridor_Elevators_Equip')
  elec_equip2.setName('Elevators_Lights_Fan')
  elec_equip1.setSpace(corridor_top_space)
  elec_equip2.setSpace(corridor_top_space)
  elec_equip1.setSchedule(model_add_schedule(model, 'ApartmentMidRise BLDG_ELEVATORS'))
  case template
    when '90.1-2004', '90.1-2007'
      elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_24_7'))
    when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
      elec_equip2.setSchedule(model_add_schedule(model, 'ApartmentMidRise ELEV_LIGHT_FAN_SCH_ADD_DF'))
  end
  return true
end

#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

geometry adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String)

    the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



160
161
162
163
164
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 160

def model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input)
  # Set original building North axis
  OpenstudioStandards::Geometry.model_set_building_north_axis(model, 0.0)
  return true
end

#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

hvac adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String)

    the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 11

def model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input)
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific HVAC adjustments')

  # add elevator and lights&fans for the ground floor corridor
  add_extra_equip_corridor(model)
  # add extra infiltration for ground floor corridor
  add_door_infiltration(climate_zone, model)

  # add transformer
  # efficiency based on a 75 kVA transformer
  case template
  when '90.1-2004', '90.1-2007'
    transformer_efficiency = 0.966
  when '90.1-2010', '90.1-2013'
    transformer_efficiency = 0.98
  when '90.1-2016', '90.1-2019'
    transformer_efficiency = 0.986
  else
    transformer_efficiency = nil
  end
  return true if transformer_efficiency.nil?

  # Change to output variable name in E+ 9.4 (OS 3.1.0)
  excluded_interiorequip_variable = if model.version < OpenStudio::VersionString.new('3.1.0')
                                      'Electric Equipment Electric Energy'
                                    else
                                      'Electric Equipment Electricity Energy'
                                    end

  model_add_transformer(model,
                        wired_lighting_frac: 0.0015,
                        transformer_size: 75000,
                        transformer_efficiency: transformer_efficiency,
                        excluded_interiorequip_key: 'T Corridor_Elevators_Equip',
                        excluded_interiorequip_meter: excluded_interiorequip_variable)

  return true
end

#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

swh adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String)

    the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



149
150
151
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 149

def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
  return true
end

#model_update_fan_efficiency(model) ⇒ Boolean

update fan efficiency

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



132
133
134
135
136
137
138
139
140
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb', line 132

def model_update_fan_efficiency(model)
  model.getFanOnOffs.sort.each do |fan_onoff|
    next if fan_onoff.name.get.to_s.include?('ERV')

    fan_onoff.setFanEfficiency(0.53625)
    fan_onoff.setMotorEfficiency(0.825)
  end
  return true