Module: MediumOfficeDetailed

Defined in:
lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb

Overview

Custom changes for the MediumOffice prototype. These are changes that are inconsistent with other prototype building types.

AirTerminalSingleDuctVAVReheat collapse

Instance Method Summary collapse

Instance Method Details

#add_door_infiltration(climate_zone, model) ⇒ Boolean

add door infiltration

Parameters:

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb', line 41

def add_door_infiltration(climate_zone, model)
  # add extra infiltration for entry door in m3/s (there is no attic in 'DOE Ref Pre-1980')
  return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'

  entry_space = model.getSpaceByName('Lounge_Bot').get
  infiltration_entrydoor = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
  infiltration_entrydoor.setName('entry door Infiltration')
  infiltration_per_zone_entrydoor = 0
  if template == '90.1-2004'
    infiltration_per_zone_entrydoor = 1.04300287
    infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH'))
  elsif template == '90.1-2007' || template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
    case climate_zone
    when 'ASHRAE 169-2006-1A', 'ASHRAE 169-2006-2A', 'ASHRAE 169-2006-1B', 'ASHRAE 169-2006-2B'
      infiltration_per_zone_entrydoor = 1.04300287
      infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH'))
    else
      infiltration_per_zone_entrydoor = 0.678659786
      infiltration_entrydoor.setSchedule(model_add_schedule(model, 'OfficeMedium INFIL_Door_Opening_SCH'))
    end
  end
  infiltration_entrydoor.setDesignFlowRate(infiltration_per_zone_entrydoor)
  infiltration_entrydoor.setSpace(entry_space)
  return true
end

#air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area) ⇒ Boolean

Set the initial minimum damper position based on OA rate of the space and the template. Zones with low OA per area get lower initial guesses. Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions

Parameters:

  • air_terminal_single_duct_vav_reheat (OpenStudio::Model::AirTerminalSingleDuctVAVReheat)

    the air terminal object

  • zone_oa_per_area (Double)

    the zone outdoor air per area in m^3/s*m^2

Returns:

  • (Boolean)

    returns true if successful, false if not



177
178
179
180
181
182
183
184
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb', line 177

def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
  min_damper_position = template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019' ? 0.2 : 0.3

  # Set the minimum flow fraction
  air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)

  return true
end

#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

geometry adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String the building type)

    uilding_type [String the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



163
164
165
166
167
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb', line 163

def model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input)
  # Set original building North axis
  OpenstudioStandards::Geometry.model_set_building_north_axis(model, 0.0)
  return true
end

#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

hvac adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String the building type)

    uilding_type [String the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb', line 11

def model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input)
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments')

  model.getSpaces.sort.each do |space|
    if space.name.get.to_s == 'Lobby_Bot'
      model_add_elevator(model,
                         space,
                         prototype_input['number_of_elevators'],
                         prototype_input['elevator_type'],
                         prototype_input['elevator_schedule'],
                         prototype_input['elevator_fan_schedule'],
                         prototype_input['elevator_fan_schedule'],
                         building_type)
    end
  end

  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished building type specific adjustments')

  # add extra infiltration for entry door
  add_door_infiltration(climate_zone, model)
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Added door infiltration')

  return true
end

#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean

swh adjustments specific to the prototype model

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

  • building_type (String the building type)

    uilding_type [String the building type

  • climate_zone (String)

    ASHRAE climate zone, e.g. ‘ASHRAE 169-2013-4A’

  • prototype_input (Hash)

    hash of prototype inputs

Returns:

  • (Boolean)

    returns true if successful, false if not



150
151
152
153
154
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb', line 150

def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
  update_waterheater_loss_coefficient(model)

  return true
end

#update_waterheater_loss_coefficient(model) ⇒ Boolean

update water heater loss coefficient

Parameters:

  • model (OpenStudio::Model::Model)

    OpenStudio model object

Returns:

  • (Boolean)

    returns true if successful, false if not



132
133
134
135
136
137
138
139
140
141
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb', line 132

def update_waterheater_loss_coefficient(model)
  case template
    when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019', 'NECB2011'
      model.getWaterHeaterMixeds.sort.each do |water_heater|
        water_heater.setOffCycleLossCoefficienttoAmbientTemperature(7.561562668)
        water_heater.setOnCycleLossCoefficienttoAmbientTemperature(7.561562668)
      end
  end
  return true
end