Module: PrimarySchool
- Defined in:
- lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb
Overview
Custom changes for the PrimarySchool prototype. These are changes that are inconsistent with other prototype building types.
AirTerminalSingleDuctVAVReheat collapse
-
#air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac) ⇒ String
Type of SAT reset for this building type.
-
#air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area) ⇒ Boolean
Set the initial minimum damper position based on OA rate of the space and the template.
-
#model_transfer_air_target_and_source_zones(model) ⇒ Hash
List transfer air target and source zones, and air flow (cfm) code_sections [90.1-2019_6.5.7.1], [90.1-2016_6.5.7.1].
Instance Method Summary collapse
-
#add_extra_equip_kitchen(model) ⇒ Boolean
add extra equipment for kitchen.
-
#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
geometry adjustments specific to the prototype model.
-
#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
hvac adjustments specific to the prototype model.
-
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
swh adjustments specific to the prototype model.
-
#update_waterheater_ambient_parameters(model) ⇒ Boolean
update water heater ambient conditions.
Instance Method Details
#add_extra_equip_kitchen(model) ⇒ Boolean
add extra equipment for kitchen
42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 42 def add_extra_equip_kitchen(model) kitchen_space = model.getSpaceByName('Kitchen_ZN_1_FLR_1') kitchen_space = kitchen_space.get kitchen_space_type = kitchen_space.spaceType.get elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def1.setName('Kitchen Electric Equipment Definition1') elec_equip_def2.setName('Kitchen Electric Equipment Definition2') case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019' elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0.25) elec_equip_def1.setFractionLost(0) elec_equip_def2.setFractionLatent(0) elec_equip_def2.setFractionRadiant(0.25) elec_equip_def2.setFractionLost(0) if template == '90.1-2013' || template == '90.1-2016' elec_equip_def1.setDesignLevel(915) elec_equip_def2.setDesignLevel(570) elsif template == '90.1-2019' elec_equip_def1.setDesignLevel(555) elec_equip_def2.setDesignLevel(313.3) else elec_equip_def1.setDesignLevel(1032) elec_equip_def2.setDesignLevel(852) end # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2) elec_equip1.setName('Kitchen_Reach-in-Freezer') elec_equip2.setName('Kitchen_Reach-in-Refrigerator') elec_equip1.setSpaceType(kitchen_space_type) elec_equip2.setSpaceType(kitchen_space_type) elec_equip1.setSchedule(model_add_schedule(model, 'SchoolPrimary ALWAYS_ON')) elec_equip2.setSchedule(model_add_schedule(model, 'SchoolPrimary ALWAYS_ON')) end return true end |
#air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac) ⇒ String
Type of SAT reset for this building type
142 143 144 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 142 def air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac) return 'oa' end |
#air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area) ⇒ Boolean
Set the initial minimum damper position based on OA rate of the space and the template. Zones with low OA per area get lower initial guesses. Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
129 130 131 132 133 134 135 136 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 129 def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area) min_damper_position = template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019' ? 0.2 : 0.3 # Set the minimum flow fraction air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position) return true end |
#model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
geometry adjustments specific to the prototype model
115 116 117 118 119 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 115 def model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input) # Set original building North axis OpenstudioStandards::Geometry.model_set_building_north_axis(model, 0.0) return true end |
#model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
hvac adjustments specific to the prototype model
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 11 def model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific HVAC adjustments') # add transformer # efficiency based on a 113 kVA transformer case template when '90.1-2004', '90.1-2007' transformer_efficiency = 0.969 when '90.1-2010', '90.1-2013' transformer_efficiency = 0.982 when '90.1-2016', '90.1-2019' transformer_efficiency = 0.987 else transformer_efficiency = nil end return true if transformer_efficiency.nil? model_add_transformer(model, wired_lighting_frac: 0.0119, transformer_size: 112500, transformer_efficiency: transformer_efficiency) # add extra equipment for kitchen add_extra_equip_kitchen(model) return true end |
#model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
swh adjustments specific to the prototype model
103 104 105 106 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 103 def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) update_waterheater_ambient_parameters(model) return true end |
#model_transfer_air_target_and_source_zones(model) ⇒ Hash
List transfer air target and source zones, and air flow (cfm) code_sections [90.1-2019_6.5.7.1], [90.1-2016_6.5.7.1]
151 152 153 154 155 156 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 151 def model_transfer_air_target_and_source_zones(model) model_transfer_air_target_and_source_zones_hash = { 'Bath_ZN_1_FLR_1 ZN' => ['Library_Media_Center_ZN_1_FLR_1 ZN', 600.0] } return model_transfer_air_target_and_source_zones_hash end |
#update_waterheater_ambient_parameters(model) ⇒ Boolean
update water heater ambient conditions
85 86 87 88 89 90 91 92 93 94 |
# File 'lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb', line 85 def update_waterheater_ambient_parameters(model) model.getWaterHeaterMixeds.sort.each do |water_heater| if water_heater.name.to_s.include?('Booster') water_heater.resetAmbientTemperatureSchedule water_heater.setAmbientTemperatureIndicator('ThermalZone') water_heater.setAmbientTemperatureThermalZone(model.getThermalZoneByName('Kitchen_ZN_1_FLR_1 ZN').get) end end return true end |