Module: Signal
- Defined in:
- signal.c
Class Method Summary collapse
-
.list ⇒ Hash
Returns a list of signal names mapped to the corresponding underlying signal numbers.
-
.signame(signo) ⇒ String?
Convert signal number to signal name.
-
.trap(*args) ⇒ Object
Specifies the handling of signals.
Instance Method Summary collapse
-
#list ⇒ Hash
private
Returns a list of signal names mapped to the corresponding underlying signal numbers.
-
#signame(signo) ⇒ String?
private
Convert signal number to signal name.
-
#trap(*args) ⇒ Object
private
Specifies the handling of signals.
Class Method Details
.list ⇒ Hash
Returns a list of signal names mapped to the corresponding underlying signal numbers.
Signal.list #=> {"EXIT"=>0, "HUP"=>1, "INT"=>2, "QUIT"=>3, "ILL"=>4, "TRAP"=>5, "IOT"=>6, "ABRT"=>6, "FPE"=>8, "KILL"=>9, "BUS"=>7, "SEGV"=>11, "SYS"=>31, "PIPE"=>13, "ALRM"=>14, "TERM"=>15, "URG"=>23, "STOP"=>19, "TSTP"=>20, "CONT"=>18, "CHLD"=>17, "CLD"=>17, "TTIN"=>21, "TTOU"=>22, "IO"=>29, "XCPU"=>24, "XFSZ"=>25, "VTALRM"=>26, "PROF"=>27, "WINCH"=>28, "USR1"=>10, "USR2"=>12, "PWR"=>30, "POLL"=>29}
1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 |
# File 'signal.c', line 1406
static VALUE
sig_list(VALUE _)
{
VALUE h = rb_hash_new();
const struct signals *sigs;
FOREACH_SIGNAL(sigs, 0) {
rb_hash_aset(h, rb_fstring_cstr(sigs->signm), INT2FIX(sigs->signo));
}
return h;
}
|
.signame(signo) ⇒ String?
Convert signal number to signal name.
Returns +nil+ if the signo is an invalid signal number.
Signal.trap("INT") { |signo| puts Signal.signame(signo) }
Process.kill("INT", 0)
<em>produces:</em>
INT
304 305 306 307 308 309 310 |
# File 'signal.c', line 304
static VALUE
sig_signame(VALUE recv, VALUE signo)
{
const char *signame = signo2signm(NUM2INT(signo));
if (!signame) return Qnil;
return rb_str_new_cstr(signame);
}
|
.trap(signal, command) ⇒ Object .trap(signal) {|| ... } ⇒ Object
Specifies the handling of signals. The first parameter is a signal name (a string such as “SIGALRM”, “SIGUSR1”, and so on) or a signal number. The characters “SIG” may be omitted from the signal name. The command or block specifies code to be run when the signal is raised. If the command is the string “IGNORE” or “SIG_IGN”, the signal will be ignored. If the command is “DEFAULT” or “SIG_DFL”, the Ruby’s default handler will be invoked. If the command is “EXIT”, the script will be terminated by the signal. If the command is “SYSTEM_DEFAULT”, the operating system’s default handler will be invoked. Otherwise, the given command or block will be run. The special signal name “EXIT” or signal number zero will be invoked just prior to program termination. trap returns the previous handler for the given signal.
Signal.trap(0, proc { puts "Terminating: #{$$}" })
Signal.trap("CLD") { puts "Child died" }
fork && Process.wait
produces:
Terminating: 27461
Child died
Terminating: 27460
1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 |
# File 'signal.c', line 1367
static VALUE
sig_trap(int argc, VALUE *argv, VALUE _)
{
int sig;
sighandler_t func;
VALUE cmd;
rb_check_arity(argc, 1, 2);
sig = trap_signm(argv[0]);
if (reserved_signal_p(sig)) {
const char *name = signo2signm(sig);
if (name)
rb_raise(rb_eArgError, "can't trap reserved signal: SIG%s", name);
else
rb_raise(rb_eArgError, "can't trap reserved signal: %d", sig);
}
if (argc == 1) {
cmd = rb_block_proc();
func = sighandler;
}
else {
cmd = argv[1];
func = trap_handler(&cmd, sig);
}
return trap(sig, func, cmd);
}
|
Instance Method Details
#list ⇒ Hash (private)
Returns a list of signal names mapped to the corresponding underlying signal numbers.
Signal.list #=> {"EXIT"=>0, "HUP"=>1, "INT"=>2, "QUIT"=>3, "ILL"=>4, "TRAP"=>5, "IOT"=>6, "ABRT"=>6, "FPE"=>8, "KILL"=>9, "BUS"=>7, "SEGV"=>11, "SYS"=>31, "PIPE"=>13, "ALRM"=>14, "TERM"=>15, "URG"=>23, "STOP"=>19, "TSTP"=>20, "CONT"=>18, "CHLD"=>17, "CLD"=>17, "TTIN"=>21, "TTOU"=>22, "IO"=>29, "XCPU"=>24, "XFSZ"=>25, "VTALRM"=>26, "PROF"=>27, "WINCH"=>28, "USR1"=>10, "USR2"=>12, "PWR"=>30, "POLL"=>29}
1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 |
# File 'signal.c', line 1406
static VALUE
sig_list(VALUE _)
{
VALUE h = rb_hash_new();
const struct signals *sigs;
FOREACH_SIGNAL(sigs, 0) {
rb_hash_aset(h, rb_fstring_cstr(sigs->signm), INT2FIX(sigs->signo));
}
return h;
}
|
#signame(signo) ⇒ String? (private)
Convert signal number to signal name.
Returns +nil+ if the signo is an invalid signal number.
Signal.trap("INT") { |signo| puts Signal.signame(signo) }
Process.kill("INT", 0)
<em>produces:</em>
INT
304 305 306 307 308 309 310 |
# File 'signal.c', line 304
static VALUE
sig_signame(VALUE recv, VALUE signo)
{
const char *signame = signo2signm(NUM2INT(signo));
if (!signame) return Qnil;
return rb_str_new_cstr(signame);
}
|
#trap(signal, command) ⇒ Object (private) #trap(signal) {|| ... } ⇒ Object (private)
Specifies the handling of signals. The first parameter is a signal name (a string such as “SIGALRM”, “SIGUSR1”, and so on) or a signal number. The characters “SIG” may be omitted from the signal name. The command or block specifies code to be run when the signal is raised. If the command is the string “IGNORE” or “SIG_IGN”, the signal will be ignored. If the command is “DEFAULT” or “SIG_DFL”, the Ruby’s default handler will be invoked. If the command is “EXIT”, the script will be terminated by the signal. If the command is “SYSTEM_DEFAULT”, the operating system’s default handler will be invoked. Otherwise, the given command or block will be run. The special signal name “EXIT” or signal number zero will be invoked just prior to program termination. trap returns the previous handler for the given signal.
Signal.trap(0, proc { puts "Terminating: #{$$}" })
Signal.trap("CLD") { puts "Child died" }
fork && Process.wait
produces:
Terminating: 27461
Child died
Terminating: 27460
1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 |
# File 'signal.c', line 1367
static VALUE
sig_trap(int argc, VALUE *argv, VALUE _)
{
int sig;
sighandler_t func;
VALUE cmd;
rb_check_arity(argc, 1, 2);
sig = trap_signm(argv[0]);
if (reserved_signal_p(sig)) {
const char *name = signo2signm(sig);
if (name)
rb_raise(rb_eArgError, "can't trap reserved signal: SIG%s", name);
else
rb_raise(rb_eArgError, "can't trap reserved signal: %d", sig);
}
if (argc == 1) {
cmd = rb_block_proc();
func = sighandler;
}
else {
cmd = argv[1];
func = trap_handler(&cmd, sig);
}
return trap(sig, func, cmd);
}
|