Class: DOERef1980to2004Warehouse
- Inherits:
-
DOERef1980to2004
- Object
- Standard
- ASHRAE901
- DOERef1980to2004
- DOERef1980to2004Warehouse
- Defined in:
- lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb
Overview
This class represents a prototypical DOERef1980to2004 Warehouse.
Constant Summary collapse
- @@building_type =
"Warehouse"
Constants inherited from Standard
Instance Attribute Summary collapse
-
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
-
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
-
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
-
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
-
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
-
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
-
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
Attributes inherited from DOERef1980to2004
Attributes inherited from Standard
#space_multiplier_map, #standards_data, #template
Instance Method Summary collapse
-
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
-
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
-
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
-
#initialize ⇒ DOERef1980to2004Warehouse
constructor
A new instance of DOERef1980to2004Warehouse.
-
#model_custom_daylighting_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
daylighting adjustments specific to the prototype model.
-
#model_get_lookup_name(building_type) ⇒ String
Get the name of the building type used in lookups.
-
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_exhaust_fan_efficiency(model) ⇒ Boolean
update exhuast fan efficiency.
-
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb.
Methods inherited from DOERef1980to2004
#air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_minimum_zone_ventilation_efficiency, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_vav_damper_action, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #load_standards_database, #model_add_elevator, #model_apply_infiltration_standard, #model_elevator_lift_power, #model_get_climate_zone_set_from_list, #model_walkin_freezer_latent_case_credit_curve, #plant_loop_supply_water_temperature_reset_required?
Methods inherited from ASHRAE901
#fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #load_standards_database
Methods inherited from Standard
#adjust_sizing_system, #afue_to_thermal_eff, #air_loop_hvac_add_motorized_oa_damper, #air_loop_hvac_adjust_minimum_vav_damper_positions, #air_loop_hvac_adjust_minimum_vav_damper_positions_outpatient, #air_loop_hvac_allowable_system_brake_horsepower, #air_loop_hvac_apply_baseline_fan_pressure_rise, #air_loop_hvac_apply_economizer_integration, #air_loop_hvac_apply_economizer_limits, #air_loop_hvac_apply_energy_recovery_ventilator, #air_loop_hvac_apply_energy_recovery_ventilator_efficiency, #air_loop_hvac_apply_maximum_reheat_temperature, #air_loop_hvac_apply_minimum_vav_damper_positions, #air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_apply_prm_baseline_controls, #air_loop_hvac_apply_prm_baseline_economizer, #air_loop_hvac_apply_prm_baseline_fan_power, #air_loop_hvac_apply_prm_sizing_temperatures, #air_loop_hvac_apply_single_zone_controls, #air_loop_hvac_apply_standard_controls, #air_loop_hvac_apply_vav_damper_action, #air_loop_hvac_data_center_area_served, #air_loop_hvac_dcv_required_when_erv, #air_loop_hvac_demand_control_ventilation_limits, #air_loop_hvac_demand_control_ventilation_required?, #air_loop_hvac_disable_multizone_vav_optimization, #air_loop_hvac_dx_cooling?, #air_loop_hvac_economizer?, #air_loop_hvac_economizer_limits, #air_loop_hvac_economizer_required?, #air_loop_hvac_economizer_type_allowable?, #air_loop_hvac_enable_demand_control_ventilation, #air_loop_hvac_enable_multizone_vav_optimization, #air_loop_hvac_enable_optimum_start, #air_loop_hvac_enable_supply_air_temperature_reset_delta, #air_loop_hvac_enable_supply_air_temperature_reset_outdoor_temperature, #air_loop_hvac_enable_supply_air_temperature_reset_warmest_zone, #air_loop_hvac_enable_unoccupied_fan_shutoff, #air_loop_hvac_energy_recovery?, #air_loop_hvac_energy_recovery_ventilator_flow_limit, #air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type, #air_loop_hvac_energy_recovery_ventilator_required?, #air_loop_hvac_energy_recovery_ventilator_type, #air_loop_hvac_fan_power_limitation_pressure_drop_adjustment_brake_horsepower, #air_loop_hvac_find_design_supply_air_flow_rate, #air_loop_hvac_floor_area_served, #air_loop_hvac_floor_area_served_exterior_zones, #air_loop_hvac_floor_area_served_interior_zones, #air_loop_hvac_get_occupancy_schedule, #air_loop_hvac_get_relief_fan_power, #air_loop_hvac_get_return_fan_power, #air_loop_hvac_get_supply_fan, #air_loop_hvac_get_supply_fan_power, #air_loop_hvac_has_parallel_piu_air_terminals?, #air_loop_hvac_has_simple_transfer_air?, #air_loop_hvac_humidifier_count, #air_loop_hvac_include_cooling_coil?, #air_loop_hvac_include_economizer?, #air_loop_hvac_include_evaporative_cooler?, #air_loop_hvac_include_hydronic_cooling_coil?, #air_loop_hvac_include_unitary_system?, #air_loop_hvac_include_wshp?, #air_loop_hvac_integrated_economizer_required?, #air_loop_hvac_minimum_zone_ventilation_efficiency, #air_loop_hvac_motorized_oa_damper_limits, #air_loop_hvac_motorized_oa_damper_required?, #air_loop_hvac_multi_stage_dx_cooling?, #air_loop_hvac_multizone_vav_optimization_required?, #air_loop_hvac_multizone_vav_system?, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_prm_baseline_economizer_required?, #air_loop_hvac_prm_economizer_type_and_limits, #air_loop_hvac_remove_erv, #air_loop_hvac_remove_motorized_oa_damper, #air_loop_hvac_residential_area_served, #air_loop_hvac_return_air_plenum, #air_loop_hvac_set_minimum_damper_position, #air_loop_hvac_set_vsd_curve_type, #air_loop_hvac_single_zone_controls_num_stages, #air_loop_hvac_standby_mode_occupancy_control, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_supply_air_temperature_reset_required?, #air_loop_hvac_supply_return_exhaust_relief_fans, #air_loop_hvac_system_fan_brake_horsepower, #air_loop_hvac_system_multiplier, #air_loop_hvac_terminal_reheat?, #air_loop_hvac_total_cooling_capacity, #air_loop_hvac_unitary_system?, #air_loop_hvac_unoccupied_fan_shutoff_required?, #air_loop_hvac_unoccupied_threshold, #air_loop_hvac_vav_damper_action, #air_loop_hvac_vav_system?, #air_terminal_single_duct_parallel_piu_reheat_apply_minimum_primary_airflow_fraction, #air_terminal_single_duct_parallel_piu_reheat_apply_prm_baseline_fan_power, #air_terminal_single_duct_parallel_piu_reheat_fan_on_flow_fraction, #air_terminal_single_duct_parallel_reheat_piu_minimum_primary_airflow_fraction, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #air_terminal_single_duct_vav_reheat_apply_minimum_damper_position, #air_terminal_single_duct_vav_reheat_minimum_damper_position, #air_terminal_single_duct_vav_reheat_reheat_type, #air_terminal_single_duct_vav_reheat_set_heating_cap, #apply_lighting_schedule, #apply_limit_to_subsurface_ratio, #boiler_get_eff_fplr, #boiler_hot_water_apply_efficiency_and_curves, #boiler_hot_water_find_capacity, #boiler_hot_water_find_design_water_flow_rate, #boiler_hot_water_find_search_criteria, #boiler_hot_water_standard_minimum_thermal_efficiency, build, #chiller_electric_eir_apply_efficiency_and_curves, #chiller_electric_eir_find_capacity, #chiller_electric_eir_find_search_criteria, #chiller_electric_eir_get_cap_f_t_curve_name, #chiller_electric_eir_get_eir_f_plr_curve_name, #chiller_electric_eir_get_eir_f_t_curve_name, #chiller_electric_eir_standard_minimum_full_load_efficiency, #chw_sizing_control, #coil_cooling_dx_multi_speed_apply_efficiency_and_curves, #coil_cooling_dx_multi_speed_find_capacity, #coil_cooling_dx_multi_speed_standard_minimum_cop, #coil_cooling_dx_single_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_find_capacity, #coil_cooling_dx_single_speed_standard_minimum_cop, #coil_cooling_dx_two_speed_apply_efficiency_and_curves, #coil_cooling_dx_two_speed_find_capacity, #coil_cooling_dx_two_speed_standard_minimum_cop, #coil_cooling_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_cooling_water_to_air_heat_pump_find_capacity, #coil_cooling_water_to_air_heat_pump_standard_minimum_cop, #coil_heating_dx_multi_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_apply_defrost_eir_curve_limits, #coil_heating_dx_single_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_find_capacity, #coil_heating_dx_single_speed_standard_minimum_cop, #coil_heating_gas_additional_search_criteria, #coil_heating_gas_apply_efficiency_and_curves, #coil_heating_gas_apply_prototype_efficiency, #coil_heating_gas_find_capacity, #coil_heating_gas_multi_stage_apply_efficiency_and_curves, #coil_heating_gas_multi_stage_find_capacity, #coil_heating_gas_multi_stage_find_search_criteria, #coil_heating_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_heating_water_to_air_heat_pump_find_capacity, #coil_heating_water_to_air_heat_pump_standard_minimum_cop, #combustion_eff_to_thermal_eff, #controller_water_coil_set_convergence_limits, #convert_curve_biquadratic, #cooling_tower_single_speed_apply_efficiency_and_curves, #cooling_tower_two_speed_apply_efficiency_and_curves, #cooling_tower_variable_speed_apply_efficiency_and_curves, #cop_heating_to_cop_heating_no_fan, #cop_no_fan_to_eer, #cop_no_fan_to_seer, #cop_to_eer, #cop_to_kw_per_ton, #cop_to_seer, #create_air_conditioner_variable_refrigerant_flow, #create_boiler_hot_water, #create_central_air_source_heat_pump, #create_coil_cooling_dx_single_speed, #create_coil_cooling_dx_two_speed, #create_coil_cooling_water, #create_coil_cooling_water_to_air_heat_pump_equation_fit, #create_coil_heating_dx_single_speed, #create_coil_heating_electric, #create_coil_heating_gas, #create_coil_heating_water, #create_coil_heating_water_to_air_heat_pump_equation_fit, #create_curve_bicubic, #create_curve_biquadratic, #create_curve_cubic, #create_curve_exponent, #create_curve_quadratic, #create_fan_constant_volume, #create_fan_constant_volume_from_json, #create_fan_on_off, #create_fan_on_off_from_json, #create_fan_variable_volume, #create_fan_variable_volume_from_json, #create_fan_zone_exhaust, #create_fan_zone_exhaust_from_json, #define_space_multiplier, #eer_to_cop, #eer_to_cop_no_fan, #ems_friendly_name, #enthalpy_recovery_ratio_design_to_typical_adjustment, #fan_constant_volume_airloop_fan_pressure_rise, #fan_constant_volume_apply_prototype_fan_pressure_rise, #fan_on_off_airloop_or_unitary_fan_pressure_rise, #fan_on_off_apply_prototype_fan_pressure_rise, #fan_variable_volume_airloop_fan_pressure_rise, #fan_variable_volume_apply_prototype_fan_pressure_rise, #fan_variable_volume_cooling_system_type, #fan_variable_volume_part_load_fan_power_limitation?, #fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #fan_variable_volume_set_control_type, #fan_zone_exhaust_apply_prototype_fan_pressure_rise, #find_exposed_conditioned_roof_surfaces, #find_exposed_conditioned_vertical_surfaces, #find_highest_roof_centre, #fluid_cooler_apply_minimum_power_per_flow, #get_avg_of_other_zones, #get_default_surface_cons_from_surface_type, #get_fan_object_for_airloop, #get_fan_schedule_for_each_zone, #get_group_heat_types, #get_outdoor_subsurface_ratio, #get_weekday_values_from_8760, #get_wtd_avg_of_other_zones, #headered_pumps_variable_speed_set_control_type, #heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency_enthalpy_recovery_ratio, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_nominal_electric_power, #heat_exchanger_air_to_air_sensible_and_latent_enthalpy_recovery_ratio_to_effectiveness, #heat_exchanger_air_to_air_sensible_and_latent_minimum_effectiveness, #heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency, #hspf_to_cop, #hspf_to_cop_no_fan, #interior_lighting_get_prm_data, #kw_per_ton_to_cop, #load_hvac_map, #load_initial_osm, #load_standards_database, #make_ruleset_sched_from_8760, #make_week_ruleset_sched_from_168, #model_add_baseboard, #model_add_cav, #model_add_central_air_source_heat_pump, #model_add_chw_loop, #model_add_construction, #model_add_construction_set, #model_add_crac, #model_add_crah, #model_add_curve, #model_add_cw_loop, #model_add_data_center_hvac, #model_add_data_center_load, #model_add_daylighting_controls, #model_add_district_ambient_loop, #model_add_doas, #model_add_doas_cold_supply, #model_add_elevator, #model_add_elevators, #model_add_evap_cooler, #model_add_exhaust_fan, #model_add_four_pipe_fan_coil, #model_add_furnace_central_ac, #model_add_ground_hx_loop, #model_add_high_temp_radiant, #model_add_hp_loop, #model_add_hvac, #model_add_hvac_system, #model_add_hw_loop, #model_add_ideal_air_loads, #model_add_low_temp_radiant, #model_add_material, #model_add_minisplit_hp, #model_add_plant_supply_water_temperature_control, #model_add_prm_baseline_system, #model_add_prm_elevators, #model_add_psz_ac, #model_add_psz_vav, #model_add_ptac, #model_add_pthp, #model_add_pvav, #model_add_pvav_pfp_boxes, #model_add_radiant_basic_controls, #model_add_radiant_proportional_controls, #model_add_refrigeration_case, #model_add_refrigeration_compressor, #model_add_refrigeration_system, #model_add_refrigeration_walkin, #model_add_residential_erv, #model_add_residential_ventilator, #model_add_schedule, #model_add_split_ac, #model_add_swh, #model_add_swh_end_uses_by_space, #model_add_transformer, #model_add_typical_exterior_lights, #model_add_typical_refrigeration, #model_add_typical_swh, #model_add_unitheater, #model_add_vav_pfp_boxes, #model_add_vav_reheat, #model_add_vrf, #model_add_water_source_hp, #model_add_waterside_economizer, #model_add_window_ac, #model_add_zone_erv, #model_add_zone_heat_cool_request_count_program, #model_add_zone_ventilation, #model_apply_baseline_exterior_lighting, #model_apply_hvac_efficiency_standard, #model_apply_infiltration_standard, #model_apply_multizone_vav_outdoor_air_sizing, #model_apply_prm_baseline_sizing_schedule, #model_apply_prm_baseline_skylight_to_roof_ratio, #model_apply_prm_baseline_window_to_wall_ratio, #model_apply_prm_construction_types, #model_apply_prm_sizing_parameters, #model_apply_standard_constructions, #model_apply_standard_infiltration, #model_baseline_system_vav_fan_type, #model_create_exterior_lighting_area_length_count_hash, #model_create_multizone_fan_schedule, #model_create_prm_any_baseline_building, #model_create_prm_baseline_building, #model_create_prm_baseline_building_requires_proposed_model_sizing_run, #model_create_prm_baseline_building_requires_vlt_sizing_run, #model_create_prm_proposed_building, #model_create_prm_stable_baseline_building, #model_create_space_type_hash, #model_create_story_hash, #model_cw_loop_cooling_tower_fan_type, #model_differentiate_primary_secondary_thermal_zones, #model_effective_num_stories, #model_elevator_fan_pwr, #model_elevator_lift_power, #model_elevator_lighting_pct_incandescent, #model_eliminate_outlier_zones, #model_find_and_add_construction, #model_find_ashrae_hot_water_demand, #model_find_climate_zone_set, #model_find_icc_iecc_2015_hot_water_demand, #model_find_icc_iecc_2015_internal_loads, #model_find_object, #model_find_objects, #model_find_prototype_floor_area, #model_find_target_eui, #model_find_target_eui_by_end_use, #model_find_water_heater_capacity_volume_and_parasitic, #model_get_baseline_system_type_by_zone, #model_get_building_properties, #model_get_climate_zone_set_from_list, #model_get_construction_properties, #model_get_construction_set, #model_get_district_heating_zones, #model_get_or_add_ambient_water_loop, #model_get_or_add_chilled_water_loop, #model_get_or_add_ground_hx_loop, #model_get_or_add_heat_pump_loop, #model_get_or_add_hot_water_loop, #model_is_hvac_autosized, #model_legacy_results_by_end_use_and_fuel_type, #model_make_name, #model_prm_baseline_system_change_fuel_type, #model_prm_baseline_system_groups, #model_prm_baseline_system_number, #model_prm_baseline_system_type, #model_prm_skylight_to_roof_ratio_limit, #model_process_results_for_datapoint, #model_remap_office, #model_remove_external_shading_devices, #model_remove_prm_ems_objects, #model_remove_prm_hvac, #model_remove_unused_resource_objects, #model_set_vav_terminals_to_control_for_outdoor_air, #model_system_outdoor_air_sizing_vrp_method, #model_two_pipe_loop, #model_typical_display_case_zone, #model_typical_hvac_system_type, #model_typical_walkin_zone, #model_validate_standards_spacetypes_in_model, #model_ventilation_method, #model_walkin_freezer_latent_case_credit_curve, #model_zones_with_occ_and_fuel_type, #planar_surface_apply_standard_construction, #plant_loop_adiabatic_pipes_only, #plant_loop_apply_prm_baseline_chilled_water_pumping_type, #plant_loop_apply_prm_baseline_chilled_water_temperatures, #plant_loop_apply_prm_baseline_condenser_water_pumping_type, #plant_loop_apply_prm_baseline_condenser_water_temperatures, #plant_loop_apply_prm_baseline_hot_water_pumping_type, #plant_loop_apply_prm_baseline_hot_water_temperatures, #plant_loop_apply_prm_baseline_pump_power, #plant_loop_apply_prm_baseline_pumping_type, #plant_loop_apply_prm_baseline_temperatures, #plant_loop_apply_prm_number_of_boilers, #plant_loop_apply_prm_number_of_chillers, #plant_loop_apply_prm_number_of_cooling_towers, #plant_loop_apply_standard_controls, #plant_loop_capacity_w_by_maxflow_and_delta_t_forwater, #plant_loop_enable_supply_water_temperature_reset, #plant_loop_find_maximum_loop_flow_rate, #plant_loop_prm_baseline_condenser_water_temperatures, #plant_loop_set_chw_pri_sec_configuration, #plant_loop_supply_water_temperature_reset_required?, #plant_loop_swh_loop?, #plant_loop_swh_system_type, #plant_loop_total_cooling_capacity, #plant_loop_total_floor_area_served, #plant_loop_total_heating_capacity, #plant_loop_total_rated_w_per_gpm, #plant_loop_variable_flow_system?, #prototype_apply_condenser_water_temperatures, #prototype_condenser_water_temperatures, #pump_variable_speed_control_type, #pump_variable_speed_get_control_type, #pump_variable_speed_set_control_type, register_standard, #remove_air_loops, #remove_all_hvac, #remove_all_plant_loops, #remove_all_zone_equipment, #remove_hvac, #remove_plant_loops, #remove_unused_curves, #remove_vrf, #remove_zone_equipment, #rename_air_loop_nodes, #rename_plant_loop_nodes, #safe_load_model, #seer_to_cop, #seer_to_cop_no_fan, #set_maximum_fraction_outdoor_air_schedule, #space_add_daylighting_controls, #space_apply_infiltration_rate, #space_conditioning_category, #space_daylighted_area_window_width, #space_daylighted_areas, #space_daylighting_control_required?, #space_daylighting_fractions_and_windows, #space_get_equip_annual_array, #space_get_loads_for_all_equips, #space_infiltration_rate_75_pa, #space_internal_load_annual_array, #space_occupancy_annual_array, #space_remove_daylighting_controls, #space_set_baseline_daylighting_controls, #space_sidelighting_effective_aperture, #space_skylight_effective_aperture, #space_type_apply_int_loads_prm, #space_type_apply_internal_load_schedules, #space_type_apply_internal_loads, #space_type_apply_rendering_color, #space_type_get_construction_properties, #space_type_get_standards_data, #space_type_light_sch_change, #standard_design_sizing_temperatures, #standards_lookup_table_first, #standards_lookup_table_many, #strip_model, #sub_surface_create_centered_subsurface_from_scaled_surface, #sub_surface_create_scaled_subsurfaces_from_surface, #surface_adjust_fenestration_in_a_surface, #surface_subsurface_ua, #thermal_eff_to_afue, #thermal_eff_to_comb_eff, #thermal_zone_add_exhaust, #thermal_zone_add_exhaust_fan_dcv, #thermal_zone_apply_prm_baseline_supply_temperatures, #thermal_zone_conditioning_category, #thermal_zone_demand_control_ventilation_limits, #thermal_zone_demand_control_ventilation_required?, #thermal_zone_exhaust_fan_dcv_required?, #thermal_zone_fossil_or_electric_type, #thermal_zone_get_annual_operating_hours, #thermal_zone_get_zone_fuels_for_occ_and_fuel_type, #thermal_zone_infer_system_type, #thermal_zone_occupancy_eflh, #thermal_zone_occupancy_type, #thermal_zone_peak_internal_load, #thermal_zone_prm_baseline_cooling_design_supply_temperature, #thermal_zone_prm_baseline_heating_design_supply_temperature, #thermal_zone_prm_lab_delta_t, #thermal_zone_prm_unitheater_design_supply_temperature, #true?, #validate_initial_model, #water_heater_convert_energy_factor_to_thermal_efficiency_and_ua, #water_heater_convert_uniform_energy_factor_to_energy_factor, #water_heater_determine_sub_type, #water_heater_mixed_additional_search_criteria, #water_heater_mixed_apply_efficiency, #water_heater_mixed_apply_prm_baseline_fuel_type, #water_heater_mixed_find_capacity, #water_heater_mixed_get_efficiency_requirement, #zone_hvac_component_apply_prm_baseline_fan_power, #zone_hvac_component_apply_standard_controls, #zone_hvac_component_apply_vestibule_heating_control, #zone_hvac_component_occupancy_ventilation_control, #zone_hvac_component_prm_baseline_fan_efficacy, #zone_hvac_component_vestibule_heating_control_required?, #zone_hvac_get_fan_object, #zone_hvac_model_standby_mode_occupancy_control, #zone_hvac_unoccupied_threshold
Methods included from PrototypeFan
apply_base_fan_variables, #create_fan_by_name, #get_fan_from_standards, #lookup_fan_curve_coefficients_from_json, #prototype_fan_apply_prototype_fan_efficiency
Methods included from CoilDX
#coil_dx_find_search_criteria, #coil_dx_heat_pump?, #coil_dx_heating_type, #coil_dx_subcategory
Methods included from CoolingTower
#cooling_tower_apply_minimum_power_per_flow, #cooling_tower_apply_minimum_power_per_flow_gpm_limit
Methods included from Pump
#pump_apply_prm_pressure_rise_and_motor_efficiency, #pump_apply_standard_minimum_motor_efficiency, #pump_brake_horsepower, #pump_motor_horsepower, #pump_pumppower, #pump_rated_w_per_gpm, #pump_standard_minimum_motor_efficiency_and_size
Methods included from Fan
#fan_adjust_pressure_rise_to_meet_fan_power, #fan_apply_standard_minimum_motor_efficiency, #fan_baseline_impeller_efficiency, #fan_brake_horsepower, #fan_change_impeller_efficiency, #fan_change_motor_efficiency, #fan_design_air_flow, #fan_fanpower, #fan_motor_horsepower, #fan_rated_w_per_cfm, #fan_small_fan?, #fan_standard_minimum_motor_efficiency_and_size
Constructor Details
#initialize ⇒ DOERef1980to2004Warehouse
Returns a new instance of DOERef1980to2004Warehouse.
24921 24922 24923 24924 24925 24926 24927 24928 24929 24930 24931 24932 24933 24934 24935 24936 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24921 def initialize super() @instvarbuilding_type = @@building_type @prototype_input = self.standards_lookup_table_first(table_name: 'prototype_inputs',search_criteria: {'template' => @template,'building_type' => @@building_type }) if @prototype_input.nil? OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Model', "Could not find prototype inputs for #{{'template' => @template,'building_type' => @@building_type }}, cannot create model.") raise("Could not find prototype inputs for DOERef1980to2004Warehouse, cannot create model.") return false end @lookup_building_type = self.model_get_lookup_name(@@building_type) #ideally we should map the data required to a instance variable. @geometry_file = 'geometry/' + @prototype_input['geometry_osm'] hvac_map_file = 'geometry/' + @prototype_input['hvac_json'] @system_to_space_map = load_hvac_map(hvac_map_file) self.set_variables() end |
Instance Attribute Details
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
24919 24920 24921 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24919 def building_story_map @building_story_map end |
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
24918 24919 24920 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24918 def geometry_file @geometry_file end |
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
24916 24917 24918 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24916 def lookup_building_type @lookup_building_type end |
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
24914 24915 24916 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24914 def prototype_database @prototype_database end |
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
24915 24916 24917 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24915 def prototype_input @prototype_input end |
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
24917 24918 24919 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24917 def space_type_map @space_type_map end |
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
24920 24921 24922 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24920 def system_to_space_map @system_to_space_map end |
Instance Method Details
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
24961 24962 24963 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24961 def define_building_story_map(building_type, climate_zone) return @building_story_map end |
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
24955 24956 24957 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24955 def define_hvac_system_map(building_type, climate_zone) return @system_to_space_map end |
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
24949 24950 24951 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24949 def define_space_type_map(building_type, climate_zone) return @space_type_map end |
#model_custom_daylighting_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
daylighting adjustments specific to the prototype model
25019 25020 25021 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 25019 def model_custom_daylighting_tweaks(model, building_type, climate_zone, prototype_input) return true end |
#model_get_lookup_name(building_type) ⇒ String
Unify the lookup names and eliminate this method
Get the name of the building type used in lookups
24987 24988 24989 24990 24991 24992 24993 24994 24995 24996 24997 24998 24999 25000 25001 25002 25003 25004 25005 25006 25007 25008 25009 25010 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24987 def model_get_lookup_name(building_type) lookup_name = building_type case building_type when 'SmallOffice' lookup_name = 'Office' when 'MediumOffice' lookup_name = 'Office' when 'LargeOffice' lookup_name = 'Office' when 'SmallOfficeDetailed' lookup_name = 'Office' when 'MediumOfficeDetailed' lookup_name = 'Office' when 'LargeOfficeDetailed' lookup_name = 'Office' when 'RetailStandalone' lookup_name = 'Retail' when 'RetailStripmall' lookup_name = 'StripMall' when 'Office' lookup_name = 'Office' end return lookup_name end |
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard
24965 24966 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24965 def model_modify_oa_controller(model) end |
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard
24968 24969 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24968 def model_reset_or_room_vav_minimum_damper(prototype_input, model) end |
#model_update_exhaust_fan_efficiency(model) ⇒ Boolean
update exhuast fan efficiency
24975 24976 24977 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24975 def model_update_exhaust_fan_efficiency(model) return true end |
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
24980 24981 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24980 def model_update_fan_efficiency(model) end |
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb. Each building type has its own set of methods that change things which are not common across all prototype buildings, even within a given Standard.
24941 24942 24943 24944 24945 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 24941 def set_variables() # Will be overwritten in class reopen file. # add all building methods for now. self.extend(Warehouse) unless @template == 'NECB 2011' end |