Class: DOERefPre1980Courthouse
- Inherits:
-
DOERefPre1980
- Object
- Standard
- ASHRAE901
- DOERefPre1980
- DOERefPre1980Courthouse
- Defined in:
- lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb
Overview
This class represents a prototypical DOERefPre1980 Courthouse.
Constant Summary collapse
- @@building_type =
"Courthouse"
Constants inherited from Standard
Instance Attribute Summary collapse
-
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
-
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
-
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
-
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
-
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
-
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
-
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
Attributes inherited from DOERefPre1980
Attributes inherited from Standard
#space_multiplier_map, #standards_data, #template
Instance Method Summary collapse
-
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
-
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
-
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
-
#initialize ⇒ DOERefPre1980Courthouse
constructor
A new instance of DOERefPre1980Courthouse.
-
#model_custom_daylighting_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
daylighting adjustments specific to the prototype model.
-
#model_get_lookup_name(building_type) ⇒ String
Get the name of the building type used in lookups.
-
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#model_update_exhaust_fan_efficiency(model) ⇒ Boolean
update exhuast fan efficiency.
-
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard.
-
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb.
Methods inherited from DOERefPre1980
#air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_minimum_zone_ventilation_efficiency, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_vav_damper_action, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #coil_heating_gas_apply_prototype_efficiency, #load_standards_database, #model_add_elevator, #model_apply_infiltration_standard, #model_elevator_lift_power, #model_get_climate_zone_set_from_list, #model_walkin_freezer_latent_case_credit_curve, #plant_loop_supply_water_temperature_reset_required?
Methods inherited from ASHRAE901
#fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #load_standards_database
Methods inherited from Standard
#adjust_sizing_system, #afue_to_thermal_eff, #air_loop_hvac_add_motorized_oa_damper, #air_loop_hvac_adjust_minimum_vav_damper_positions, #air_loop_hvac_adjust_minimum_vav_damper_positions_outpatient, #air_loop_hvac_allowable_system_brake_horsepower, #air_loop_hvac_apply_baseline_fan_pressure_rise, #air_loop_hvac_apply_economizer_integration, #air_loop_hvac_apply_economizer_limits, #air_loop_hvac_apply_energy_recovery_ventilator, #air_loop_hvac_apply_energy_recovery_ventilator_efficiency, #air_loop_hvac_apply_maximum_reheat_temperature, #air_loop_hvac_apply_minimum_vav_damper_positions, #air_loop_hvac_apply_multizone_vav_outdoor_air_sizing, #air_loop_hvac_apply_prm_baseline_controls, #air_loop_hvac_apply_prm_baseline_economizer, #air_loop_hvac_apply_prm_baseline_fan_power, #air_loop_hvac_apply_prm_sizing_temperatures, #air_loop_hvac_apply_single_zone_controls, #air_loop_hvac_apply_standard_controls, #air_loop_hvac_apply_vav_damper_action, #air_loop_hvac_data_center_area_served, #air_loop_hvac_dcv_required_when_erv, #air_loop_hvac_demand_control_ventilation_limits, #air_loop_hvac_demand_control_ventilation_required?, #air_loop_hvac_disable_multizone_vav_optimization, #air_loop_hvac_dx_cooling?, #air_loop_hvac_economizer?, #air_loop_hvac_economizer_limits, #air_loop_hvac_economizer_required?, #air_loop_hvac_economizer_type_allowable?, #air_loop_hvac_enable_demand_control_ventilation, #air_loop_hvac_enable_multizone_vav_optimization, #air_loop_hvac_enable_optimum_start, #air_loop_hvac_enable_supply_air_temperature_reset_delta, #air_loop_hvac_enable_supply_air_temperature_reset_outdoor_temperature, #air_loop_hvac_enable_supply_air_temperature_reset_warmest_zone, #air_loop_hvac_enable_unoccupied_fan_shutoff, #air_loop_hvac_energy_recovery?, #air_loop_hvac_energy_recovery_ventilator_flow_limit, #air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type, #air_loop_hvac_energy_recovery_ventilator_required?, #air_loop_hvac_energy_recovery_ventilator_type, #air_loop_hvac_fan_power_limitation_pressure_drop_adjustment_brake_horsepower, #air_loop_hvac_find_design_supply_air_flow_rate, #air_loop_hvac_floor_area_served, #air_loop_hvac_floor_area_served_exterior_zones, #air_loop_hvac_floor_area_served_interior_zones, #air_loop_hvac_get_occupancy_schedule, #air_loop_hvac_get_relief_fan_power, #air_loop_hvac_get_return_fan_power, #air_loop_hvac_get_supply_fan, #air_loop_hvac_get_supply_fan_power, #air_loop_hvac_has_parallel_piu_air_terminals?, #air_loop_hvac_has_simple_transfer_air?, #air_loop_hvac_humidifier_count, #air_loop_hvac_include_cooling_coil?, #air_loop_hvac_include_economizer?, #air_loop_hvac_include_evaporative_cooler?, #air_loop_hvac_include_hydronic_cooling_coil?, #air_loop_hvac_include_unitary_system?, #air_loop_hvac_include_wshp?, #air_loop_hvac_integrated_economizer_required?, #air_loop_hvac_minimum_zone_ventilation_efficiency, #air_loop_hvac_motorized_oa_damper_limits, #air_loop_hvac_motorized_oa_damper_required?, #air_loop_hvac_multi_stage_dx_cooling?, #air_loop_hvac_multizone_vav_optimization_required?, #air_loop_hvac_multizone_vav_system?, #air_loop_hvac_optimum_start_required?, #air_loop_hvac_prm_baseline_economizer_required?, #air_loop_hvac_prm_economizer_type_and_limits, #air_loop_hvac_remove_erv, #air_loop_hvac_remove_motorized_oa_damper, #air_loop_hvac_residential_area_served, #air_loop_hvac_return_air_plenum, #air_loop_hvac_set_minimum_damper_position, #air_loop_hvac_set_vsd_curve_type, #air_loop_hvac_single_zone_controls_num_stages, #air_loop_hvac_standby_mode_occupancy_control, #air_loop_hvac_static_pressure_reset_required?, #air_loop_hvac_supply_air_temperature_reset_required?, #air_loop_hvac_supply_return_exhaust_relief_fans, #air_loop_hvac_system_fan_brake_horsepower, #air_loop_hvac_system_multiplier, #air_loop_hvac_terminal_reheat?, #air_loop_hvac_total_cooling_capacity, #air_loop_hvac_unitary_system?, #air_loop_hvac_unoccupied_fan_shutoff_required?, #air_loop_hvac_unoccupied_threshold, #air_loop_hvac_vav_damper_action, #air_loop_hvac_vav_system?, #air_terminal_single_duct_parallel_piu_reheat_apply_minimum_primary_airflow_fraction, #air_terminal_single_duct_parallel_piu_reheat_apply_prm_baseline_fan_power, #air_terminal_single_duct_parallel_piu_reheat_fan_on_flow_fraction, #air_terminal_single_duct_parallel_reheat_piu_minimum_primary_airflow_fraction, #air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position, #air_terminal_single_duct_vav_reheat_apply_minimum_damper_position, #air_terminal_single_duct_vav_reheat_minimum_damper_position, #air_terminal_single_duct_vav_reheat_reheat_type, #air_terminal_single_duct_vav_reheat_set_heating_cap, #apply_lighting_schedule, #apply_limit_to_subsurface_ratio, #boiler_get_eff_fplr, #boiler_hot_water_apply_efficiency_and_curves, #boiler_hot_water_find_capacity, #boiler_hot_water_find_design_water_flow_rate, #boiler_hot_water_find_search_criteria, #boiler_hot_water_standard_minimum_thermal_efficiency, build, #chiller_electric_eir_apply_efficiency_and_curves, #chiller_electric_eir_find_capacity, #chiller_electric_eir_find_search_criteria, #chiller_electric_eir_get_cap_f_t_curve_name, #chiller_electric_eir_get_eir_f_plr_curve_name, #chiller_electric_eir_get_eir_f_t_curve_name, #chiller_electric_eir_standard_minimum_full_load_efficiency, #chw_sizing_control, #coil_cooling_dx_multi_speed_apply_efficiency_and_curves, #coil_cooling_dx_multi_speed_find_capacity, #coil_cooling_dx_multi_speed_standard_minimum_cop, #coil_cooling_dx_single_speed_apply_efficiency_and_curves, #coil_cooling_dx_single_speed_find_capacity, #coil_cooling_dx_single_speed_standard_minimum_cop, #coil_cooling_dx_two_speed_apply_efficiency_and_curves, #coil_cooling_dx_two_speed_find_capacity, #coil_cooling_dx_two_speed_standard_minimum_cop, #coil_cooling_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_cooling_water_to_air_heat_pump_find_capacity, #coil_cooling_water_to_air_heat_pump_standard_minimum_cop, #coil_heating_dx_multi_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_apply_defrost_eir_curve_limits, #coil_heating_dx_single_speed_apply_efficiency_and_curves, #coil_heating_dx_single_speed_find_capacity, #coil_heating_dx_single_speed_standard_minimum_cop, #coil_heating_gas_additional_search_criteria, #coil_heating_gas_apply_efficiency_and_curves, #coil_heating_gas_apply_prototype_efficiency, #coil_heating_gas_find_capacity, #coil_heating_gas_multi_stage_apply_efficiency_and_curves, #coil_heating_gas_multi_stage_find_capacity, #coil_heating_gas_multi_stage_find_search_criteria, #coil_heating_water_to_air_heat_pump_apply_efficiency_and_curves, #coil_heating_water_to_air_heat_pump_find_capacity, #coil_heating_water_to_air_heat_pump_standard_minimum_cop, #combustion_eff_to_thermal_eff, #controller_water_coil_set_convergence_limits, #convert_curve_biquadratic, #cooling_tower_single_speed_apply_efficiency_and_curves, #cooling_tower_two_speed_apply_efficiency_and_curves, #cooling_tower_variable_speed_apply_efficiency_and_curves, #cop_heating_to_cop_heating_no_fan, #cop_no_fan_to_eer, #cop_no_fan_to_seer, #cop_to_eer, #cop_to_kw_per_ton, #cop_to_seer, #create_air_conditioner_variable_refrigerant_flow, #create_boiler_hot_water, #create_central_air_source_heat_pump, #create_coil_cooling_dx_single_speed, #create_coil_cooling_dx_two_speed, #create_coil_cooling_water, #create_coil_cooling_water_to_air_heat_pump_equation_fit, #create_coil_heating_dx_single_speed, #create_coil_heating_electric, #create_coil_heating_gas, #create_coil_heating_water, #create_coil_heating_water_to_air_heat_pump_equation_fit, #create_curve_bicubic, #create_curve_biquadratic, #create_curve_cubic, #create_curve_exponent, #create_curve_quadratic, #create_fan_constant_volume, #create_fan_constant_volume_from_json, #create_fan_on_off, #create_fan_on_off_from_json, #create_fan_variable_volume, #create_fan_variable_volume_from_json, #create_fan_zone_exhaust, #create_fan_zone_exhaust_from_json, #define_space_multiplier, #eer_to_cop, #eer_to_cop_no_fan, #ems_friendly_name, #enthalpy_recovery_ratio_design_to_typical_adjustment, #fan_constant_volume_airloop_fan_pressure_rise, #fan_constant_volume_apply_prototype_fan_pressure_rise, #fan_on_off_airloop_or_unitary_fan_pressure_rise, #fan_on_off_apply_prototype_fan_pressure_rise, #fan_variable_volume_airloop_fan_pressure_rise, #fan_variable_volume_apply_prototype_fan_pressure_rise, #fan_variable_volume_cooling_system_type, #fan_variable_volume_part_load_fan_power_limitation?, #fan_variable_volume_part_load_fan_power_limitation_capacity_limit, #fan_variable_volume_part_load_fan_power_limitation_hp_limit, #fan_variable_volume_set_control_type, #fan_zone_exhaust_apply_prototype_fan_pressure_rise, #find_exposed_conditioned_roof_surfaces, #find_exposed_conditioned_vertical_surfaces, #find_highest_roof_centre, #fluid_cooler_apply_minimum_power_per_flow, #get_avg_of_other_zones, #get_default_surface_cons_from_surface_type, #get_fan_object_for_airloop, #get_fan_schedule_for_each_zone, #get_group_heat_types, #get_outdoor_subsurface_ratio, #get_weekday_values_from_8760, #get_wtd_avg_of_other_zones, #headered_pumps_variable_speed_set_control_type, #heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency_enthalpy_recovery_ratio, #heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_nominal_electric_power, #heat_exchanger_air_to_air_sensible_and_latent_enthalpy_recovery_ratio_to_effectiveness, #heat_exchanger_air_to_air_sensible_and_latent_minimum_effectiveness, #heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency, #hspf_to_cop, #hspf_to_cop_no_fan, #interior_lighting_get_prm_data, #kw_per_ton_to_cop, #load_hvac_map, #load_initial_osm, #load_standards_database, #make_ruleset_sched_from_8760, #make_week_ruleset_sched_from_168, #model_add_baseboard, #model_add_cav, #model_add_central_air_source_heat_pump, #model_add_chw_loop, #model_add_construction, #model_add_construction_set, #model_add_crac, #model_add_crah, #model_add_curve, #model_add_cw_loop, #model_add_data_center_hvac, #model_add_data_center_load, #model_add_daylighting_controls, #model_add_district_ambient_loop, #model_add_doas, #model_add_doas_cold_supply, #model_add_elevator, #model_add_elevators, #model_add_evap_cooler, #model_add_exhaust_fan, #model_add_four_pipe_fan_coil, #model_add_furnace_central_ac, #model_add_ground_hx_loop, #model_add_high_temp_radiant, #model_add_hp_loop, #model_add_hvac, #model_add_hvac_system, #model_add_hw_loop, #model_add_ideal_air_loads, #model_add_low_temp_radiant, #model_add_material, #model_add_minisplit_hp, #model_add_plant_supply_water_temperature_control, #model_add_prm_baseline_system, #model_add_prm_elevators, #model_add_psz_ac, #model_add_psz_vav, #model_add_ptac, #model_add_pthp, #model_add_pvav, #model_add_pvav_pfp_boxes, #model_add_radiant_basic_controls, #model_add_radiant_proportional_controls, #model_add_refrigeration_case, #model_add_refrigeration_compressor, #model_add_refrigeration_system, #model_add_refrigeration_walkin, #model_add_residential_erv, #model_add_residential_ventilator, #model_add_schedule, #model_add_split_ac, #model_add_swh, #model_add_swh_end_uses_by_space, #model_add_transformer, #model_add_typical_exterior_lights, #model_add_typical_refrigeration, #model_add_typical_swh, #model_add_unitheater, #model_add_vav_pfp_boxes, #model_add_vav_reheat, #model_add_vrf, #model_add_water_source_hp, #model_add_waterside_economizer, #model_add_window_ac, #model_add_zone_erv, #model_add_zone_heat_cool_request_count_program, #model_add_zone_ventilation, #model_apply_baseline_exterior_lighting, #model_apply_hvac_efficiency_standard, #model_apply_infiltration_standard, #model_apply_multizone_vav_outdoor_air_sizing, #model_apply_prm_baseline_sizing_schedule, #model_apply_prm_baseline_skylight_to_roof_ratio, #model_apply_prm_baseline_window_to_wall_ratio, #model_apply_prm_construction_types, #model_apply_prm_sizing_parameters, #model_apply_standard_constructions, #model_apply_standard_infiltration, #model_baseline_system_vav_fan_type, #model_create_exterior_lighting_area_length_count_hash, #model_create_multizone_fan_schedule, #model_create_prm_any_baseline_building, #model_create_prm_baseline_building, #model_create_prm_baseline_building_requires_proposed_model_sizing_run, #model_create_prm_baseline_building_requires_vlt_sizing_run, #model_create_prm_proposed_building, #model_create_prm_stable_baseline_building, #model_create_space_type_hash, #model_create_story_hash, #model_cw_loop_cooling_tower_fan_type, #model_differentiate_primary_secondary_thermal_zones, #model_effective_num_stories, #model_elevator_fan_pwr, #model_elevator_lift_power, #model_elevator_lighting_pct_incandescent, #model_eliminate_outlier_zones, #model_find_and_add_construction, #model_find_ashrae_hot_water_demand, #model_find_climate_zone_set, #model_find_icc_iecc_2015_hot_water_demand, #model_find_icc_iecc_2015_internal_loads, #model_find_object, #model_find_objects, #model_find_prototype_floor_area, #model_find_target_eui, #model_find_target_eui_by_end_use, #model_find_water_heater_capacity_volume_and_parasitic, #model_get_baseline_system_type_by_zone, #model_get_building_properties, #model_get_climate_zone_set_from_list, #model_get_construction_properties, #model_get_construction_set, #model_get_district_heating_zones, #model_get_or_add_ambient_water_loop, #model_get_or_add_chilled_water_loop, #model_get_or_add_ground_hx_loop, #model_get_or_add_heat_pump_loop, #model_get_or_add_hot_water_loop, #model_is_hvac_autosized, #model_legacy_results_by_end_use_and_fuel_type, #model_make_name, #model_prm_baseline_system_change_fuel_type, #model_prm_baseline_system_groups, #model_prm_baseline_system_number, #model_prm_baseline_system_type, #model_prm_skylight_to_roof_ratio_limit, #model_process_results_for_datapoint, #model_remap_office, #model_remove_external_shading_devices, #model_remove_prm_ems_objects, #model_remove_prm_hvac, #model_remove_unused_resource_objects, #model_set_vav_terminals_to_control_for_outdoor_air, #model_system_outdoor_air_sizing_vrp_method, #model_two_pipe_loop, #model_typical_display_case_zone, #model_typical_hvac_system_type, #model_typical_walkin_zone, #model_validate_standards_spacetypes_in_model, #model_ventilation_method, #model_walkin_freezer_latent_case_credit_curve, #model_zones_with_occ_and_fuel_type, #planar_surface_apply_standard_construction, #plant_loop_adiabatic_pipes_only, #plant_loop_apply_prm_baseline_chilled_water_pumping_type, #plant_loop_apply_prm_baseline_chilled_water_temperatures, #plant_loop_apply_prm_baseline_condenser_water_pumping_type, #plant_loop_apply_prm_baseline_condenser_water_temperatures, #plant_loop_apply_prm_baseline_hot_water_pumping_type, #plant_loop_apply_prm_baseline_hot_water_temperatures, #plant_loop_apply_prm_baseline_pump_power, #plant_loop_apply_prm_baseline_pumping_type, #plant_loop_apply_prm_baseline_temperatures, #plant_loop_apply_prm_number_of_boilers, #plant_loop_apply_prm_number_of_chillers, #plant_loop_apply_prm_number_of_cooling_towers, #plant_loop_apply_standard_controls, #plant_loop_capacity_w_by_maxflow_and_delta_t_forwater, #plant_loop_enable_supply_water_temperature_reset, #plant_loop_find_maximum_loop_flow_rate, #plant_loop_prm_baseline_condenser_water_temperatures, #plant_loop_set_chw_pri_sec_configuration, #plant_loop_supply_water_temperature_reset_required?, #plant_loop_swh_loop?, #plant_loop_swh_system_type, #plant_loop_total_cooling_capacity, #plant_loop_total_floor_area_served, #plant_loop_total_heating_capacity, #plant_loop_total_rated_w_per_gpm, #plant_loop_variable_flow_system?, #prototype_apply_condenser_water_temperatures, #prototype_condenser_water_temperatures, #pump_variable_speed_control_type, #pump_variable_speed_get_control_type, #pump_variable_speed_set_control_type, register_standard, #remove_air_loops, #remove_all_hvac, #remove_all_plant_loops, #remove_all_zone_equipment, #remove_hvac, #remove_plant_loops, #remove_unused_curves, #remove_vrf, #remove_zone_equipment, #rename_air_loop_nodes, #rename_plant_loop_nodes, #safe_load_model, #seer_to_cop, #seer_to_cop_no_fan, #set_maximum_fraction_outdoor_air_schedule, #space_add_daylighting_controls, #space_apply_infiltration_rate, #space_conditioning_category, #space_daylighted_area_window_width, #space_daylighted_areas, #space_daylighting_control_required?, #space_daylighting_fractions_and_windows, #space_get_equip_annual_array, #space_get_loads_for_all_equips, #space_infiltration_rate_75_pa, #space_internal_load_annual_array, #space_occupancy_annual_array, #space_remove_daylighting_controls, #space_set_baseline_daylighting_controls, #space_sidelighting_effective_aperture, #space_skylight_effective_aperture, #space_type_apply_int_loads_prm, #space_type_apply_internal_load_schedules, #space_type_apply_internal_loads, #space_type_apply_rendering_color, #space_type_get_construction_properties, #space_type_get_standards_data, #space_type_light_sch_change, #standard_design_sizing_temperatures, #standards_lookup_table_first, #standards_lookup_table_many, #strip_model, #sub_surface_create_centered_subsurface_from_scaled_surface, #sub_surface_create_scaled_subsurfaces_from_surface, #surface_adjust_fenestration_in_a_surface, #surface_subsurface_ua, #thermal_eff_to_afue, #thermal_eff_to_comb_eff, #thermal_zone_add_exhaust, #thermal_zone_add_exhaust_fan_dcv, #thermal_zone_apply_prm_baseline_supply_temperatures, #thermal_zone_conditioning_category, #thermal_zone_demand_control_ventilation_limits, #thermal_zone_demand_control_ventilation_required?, #thermal_zone_exhaust_fan_dcv_required?, #thermal_zone_fossil_or_electric_type, #thermal_zone_get_annual_operating_hours, #thermal_zone_get_zone_fuels_for_occ_and_fuel_type, #thermal_zone_infer_system_type, #thermal_zone_occupancy_eflh, #thermal_zone_occupancy_type, #thermal_zone_peak_internal_load, #thermal_zone_prm_baseline_cooling_design_supply_temperature, #thermal_zone_prm_baseline_heating_design_supply_temperature, #thermal_zone_prm_lab_delta_t, #thermal_zone_prm_unitheater_design_supply_temperature, #true?, #validate_initial_model, #water_heater_convert_energy_factor_to_thermal_efficiency_and_ua, #water_heater_convert_uniform_energy_factor_to_energy_factor, #water_heater_determine_sub_type, #water_heater_mixed_additional_search_criteria, #water_heater_mixed_apply_efficiency, #water_heater_mixed_apply_prm_baseline_fuel_type, #water_heater_mixed_find_capacity, #water_heater_mixed_get_efficiency_requirement, #zone_hvac_component_apply_prm_baseline_fan_power, #zone_hvac_component_apply_standard_controls, #zone_hvac_component_apply_vestibule_heating_control, #zone_hvac_component_occupancy_ventilation_control, #zone_hvac_component_prm_baseline_fan_efficacy, #zone_hvac_component_vestibule_heating_control_required?, #zone_hvac_get_fan_object, #zone_hvac_model_standby_mode_occupancy_control, #zone_hvac_unoccupied_threshold
Methods included from PrototypeFan
apply_base_fan_variables, #create_fan_by_name, #get_fan_from_standards, #lookup_fan_curve_coefficients_from_json, #prototype_fan_apply_prototype_fan_efficiency
Methods included from CoilDX
#coil_dx_find_search_criteria, #coil_dx_heat_pump?, #coil_dx_heating_type, #coil_dx_subcategory
Methods included from CoolingTower
#cooling_tower_apply_minimum_power_per_flow, #cooling_tower_apply_minimum_power_per_flow_gpm_limit
Methods included from Pump
#pump_apply_prm_pressure_rise_and_motor_efficiency, #pump_apply_standard_minimum_motor_efficiency, #pump_brake_horsepower, #pump_motor_horsepower, #pump_pumppower, #pump_rated_w_per_gpm, #pump_standard_minimum_motor_efficiency_and_size
Methods included from Fan
#fan_adjust_pressure_rise_to_meet_fan_power, #fan_apply_standard_minimum_motor_efficiency, #fan_baseline_impeller_efficiency, #fan_brake_horsepower, #fan_change_impeller_efficiency, #fan_change_motor_efficiency, #fan_design_air_flow, #fan_fanpower, #fan_motor_horsepower, #fan_rated_w_per_cfm, #fan_small_fan?, #fan_standard_minimum_motor_efficiency_and_size
Constructor Details
#initialize ⇒ DOERefPre1980Courthouse
Returns a new instance of DOERefPre1980Courthouse.
29488 29489 29490 29491 29492 29493 29494 29495 29496 29497 29498 29499 29500 29501 29502 29503 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29488 def initialize super() @instvarbuilding_type = @@building_type @prototype_input = self.standards_lookup_table_first(table_name: 'prototype_inputs',search_criteria: {'template' => @template,'building_type' => @@building_type }) if @prototype_input.nil? OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Model', "Could not find prototype inputs for #{{'template' => @template,'building_type' => @@building_type }}, cannot create model.") raise("Could not find prototype inputs for DOERefPre1980Courthouse, cannot create model.") return false end @lookup_building_type = self.model_get_lookup_name(@@building_type) #ideally we should map the data required to a instance variable. @geometry_file = 'geometry/' + @prototype_input['geometry_osm'] hvac_map_file = 'geometry/' + @prototype_input['hvac_json'] @system_to_space_map = load_hvac_map(hvac_map_file) self.set_variables() end |
Instance Attribute Details
#building_story_map ⇒ Object
Returns the value of attribute building_story_map.
29486 29487 29488 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29486 def building_story_map @building_story_map end |
#geometry_file ⇒ Object
Returns the value of attribute geometry_file.
29485 29486 29487 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29485 def geometry_file @geometry_file end |
#lookup_building_type ⇒ Object
Returns the value of attribute lookup_building_type.
29483 29484 29485 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29483 def lookup_building_type @lookup_building_type end |
#prototype_database ⇒ Object
Returns the value of attribute prototype_database.
29481 29482 29483 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29481 def prototype_database @prototype_database end |
#prototype_input ⇒ Object
Returns the value of attribute prototype_input.
29482 29483 29484 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29482 def prototype_input @prototype_input end |
#space_type_map ⇒ Object
Returns the value of attribute space_type_map.
29484 29485 29486 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29484 def space_type_map @space_type_map end |
#system_to_space_map ⇒ Object
Returns the value of attribute system_to_space_map.
29487 29488 29489 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29487 def system_to_space_map @system_to_space_map end |
Instance Method Details
#define_building_story_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the building story that they are located on.
29528 29529 29530 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29528 def define_building_story_map(building_type, climate_zone) return @building_story_map end |
#define_hvac_system_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the HVAC system that will be applied to those spaces.
29522 29523 29524 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29522 def define_hvac_system_map(building_type, climate_zone) return @system_to_space_map end |
#define_space_type_map(building_type, climate_zone) ⇒ Object
Returns the mapping between the names of the spaces in the geometry .osm file and the space types available for this particular Standard.
29516 29517 29518 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29516 def define_space_type_map(building_type, climate_zone) return @space_type_map end |
#model_custom_daylighting_tweaks(model, building_type, climate_zone, prototype_input) ⇒ Boolean
daylighting adjustments specific to the prototype model
29586 29587 29588 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29586 def model_custom_daylighting_tweaks(model, building_type, climate_zone, prototype_input) return true end |
#model_get_lookup_name(building_type) ⇒ String
Unify the lookup names and eliminate this method
Get the name of the building type used in lookups
29554 29555 29556 29557 29558 29559 29560 29561 29562 29563 29564 29565 29566 29567 29568 29569 29570 29571 29572 29573 29574 29575 29576 29577 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29554 def model_get_lookup_name(building_type) lookup_name = building_type case building_type when 'SmallOffice' lookup_name = 'Office' when 'MediumOffice' lookup_name = 'Office' when 'LargeOffice' lookup_name = 'Office' when 'SmallOfficeDetailed' lookup_name = 'Office' when 'MediumOfficeDetailed' lookup_name = 'Office' when 'LargeOfficeDetailed' lookup_name = 'Office' when 'RetailStandalone' lookup_name = 'Retail' when 'RetailStripmall' lookup_name = 'StripMall' when 'Office' lookup_name = 'Office' end return lookup_name end |
#model_modify_oa_controller(model) ⇒ Object
Does nothing unless implmented by the specific standard
29532 29533 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29532 def model_modify_oa_controller(model) end |
#model_reset_or_room_vav_minimum_damper(prototype_input, model) ⇒ Object
Does nothing unless implmented by the specific standard
29535 29536 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29535 def model_reset_or_room_vav_minimum_damper(prototype_input, model) end |
#model_update_exhaust_fan_efficiency(model) ⇒ Boolean
update exhuast fan efficiency
29542 29543 29544 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29542 def model_update_exhaust_fan_efficiency(model) return true end |
#model_update_fan_efficiency(model) ⇒ Object
Does nothing unless implmented by the specific standard
29547 29548 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29547 def model_update_fan_efficiency(model) end |
#set_variables ⇒ Object
This method is used to extend the class with building-type-specific methods, as defined in Prototype.SomeBuildingType.rb. Each building type has its own set of methods that change things which are not common across all prototype buildings, even within a given Standard.
29508 29509 29510 29511 29512 |
# File 'lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb', line 29508 def set_variables() # Will be overwritten in class reopen file. # add all building methods for now. self.extend(Courthouse) unless @template == 'NECB 2011' end |